A clinical-laboratory approach contributing to a rapid and reliable diagnosis of heparin-induced thrombocytopenia

被引:44
作者
Denys, Barbara [1 ]
Stove, Veronique [1 ]
Philippe, Jan [1 ]
Devreese, Katrien [1 ]
机构
[1] Ghent Univ Hosp, Dept Clin Chem Microbiol & Immunol, B-9000 Ghent, Belgium
关键词
Heparin-induced thrombocytopenia; Flow cytometry; 4T's; ELISA; Particle gel immunoassay; Bayesian diagnostic approach;
D O I
10.1016/j.thromres.2008.04.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Heparin-induced thrombocytopenia (HIT) remains a very challenging diagnosis. The first objective of this study was to compare the performance of the IDH/PF4 PaGIA (R) with the Asserachrom (R) HPIA ELISA. The main purpose was to evaluate the diagnostic utility of the combination of the H/PF4PaGIA (R) with the clinical "4T's" score as a screening strategy. Materials and Methods: 102 patients with clinical suspicion of HIT were classified into risk groups using the 4T's score. The presence of HIT antibodies was assessed by two immunoassays and confirmed by a functional flow cytometric assay. Results: Comparison of the ID-H/PF4 PaGIA (R) with the Asserachrom (R) HPIA ELISA demonstrated a comparable technical performance, being an excellent screening test to rule out HIT (negative predictive value or NPV=100%). According to the 4T's score, HIT was excluded in all tow risk patients (NPV=100%). ELISA optical density levels were significantly different between all riskgroups (P-values<0.01). In contrast, due to the tow positive predictive value (22%) and weak positive likelihood ratio (2.6), a positive ID-H/PF4 PaGIA (R) result did not considerably increase the probability of HIT. Conclusion: Our study confirms the combination of the 4T's score with the ID-H/PF4 PaGIA (R) as a reliable strategy to rule out HIT. Yet, confirming positive ID-H/PF4 PaGIA (R) results by flow cytometry within 1-2 h after blood sampling remains necessary. This novel clinical-laboratory approach can contribute in a rapid and reliable way to the definite diagnosis of HIT. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:137 / 145
页数:9
相关论文
共 29 条
[11]  
Jy W, 1999, THROMB HAEMOSTASIS, V82, P1255
[12]   The management of heparin-induced thrombocytopenia [J].
Keeling, D ;
Davidson, S ;
Watson, H .
BRITISH JOURNAL OF HAEMATOLOGY, 2006, 133 (03) :259-269
[13]   Evaluation of pretest clinical score (4 T's) for the diagnosis of heparin-induced thrombocytopenia in two clinical settings [J].
Lo, GK ;
Juhl, D ;
Warkentin, TE ;
Sigouin, CS ;
Eichler, P ;
Greinacher, A .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (04) :759-765
[14]   What is the potential for overdiagnosis of heparin-induced thrombocytopenia? [J].
Lo, Gregory K. ;
Sigouin, Christopher S. ;
Warkentin, Theodore E. .
AMERICAN JOURNAL OF HEMATOLOGY, 2007, 82 (12) :1037-1043
[15]   Heparin-induced thrombocytopenia in the critical care setting: Diagnosis and management [J].
Napolitano, Lena M. ;
Warkentin, Theodore E. ;
AlMahameed, Amjad ;
Nasraway, Stanley A. .
CRITICAL CARE MEDICINE, 2006, 34 (12) :2898-2911
[16]   Laboratory diagnosis of heparin-induced thrombocytopenia: advantages of a functional flow cytometric test in comparison to the heparin-induced platelet-activation test [J].
Poley, S ;
Mempel, W .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2001, 66 (04) :253-262
[17]   Prospective evaluation of the '4Ts' score and particle gel immunoassay specific to heparin/PF4 for the diagnosis of heparin-induced thrombocytopenia [J].
Pouplard, C. ;
Gueret, P. ;
Fouassier, M. ;
Ternisien, C. ;
Trossaert, M. ;
Regina, S. ;
Gruel, Y. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (07) :1373-1379
[18]  
Tomer A, 1999, AM J HEMATOL, V61, P53
[19]   A sensitive and specific functional flow cytometric assay for the diagnosis of heparin-induced thrombocytopenia [J].
Tomer, A .
BRITISH JOURNAL OF HAEMATOLOGY, 1997, 98 (03) :648-656
[20]   Comparison between different laboratory tests for the detection and prevention of heparin-induced thrombocytopenia [J].
Vitale, M ;
Tazzari, P ;
Ricci, F ;
Mazza, MA ;
Zauli, G ;
Martini, G ;
Caimi, L ;
Manzoli, FA ;
Conte, R .
CYTOMETRY, 2001, 46 (05) :290-295