Controlling the selectivity of glassy carbon flow detectors using covalently attached monolayers

被引:22
作者
Downard, AJ
Roddick, AD
机构
[1] Department of Chemistry, University of Canterbury
关键词
flow analysis; covalently modified glassy carbon electrodes; selectivity; monolayers;
D O I
10.1002/elan.1140090908
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Significant improvements in selectivity for amperometric detection in flow analysis are achieved at covalently modified glassy carbon electrodes. Flow detectors modified with p-alkylbenzene (alkyl = methyl, decyl) and p-phenylacetate monolayers demonstrate how selectivity may be obtained on the basis of solute hydrophobicity and charge. The modified electrodes are stable under hydrodynamic conditions and in aqueous and mixed aqueous/organic carrier streams.
引用
收藏
页码:693 / 698
页数:6
相关论文
共 22 条
[1]   INNOVATIONS IN STUDY OF ADSORBED REACTANTS BY CHRONOCOULOMETRY [J].
ANSON, FC .
ANALYTICAL CHEMISTRY, 1966, 38 (01) :54-&
[2]   IMMOBILIZATION OF GLUCOSE-OXIDASE ON A CARBON SURFACE DERIVATIZED BY ELECTROCHEMICAL REDUCTION OF DIAZONIUM SALTS [J].
BOURDILLON, C ;
DELAMAR, M ;
DEMAILLE, C ;
HITMI, R ;
MOIROUX, J ;
PINSON, J .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 336 (1-2) :113-123
[3]   COVALENT MODIFICATION OF CARBON SURFACES BY GRAFTING OF FUNCTIONALIZED ARYL RADICALS PRODUCED FROM ELECTROCHEMICAL REDUCTION OF DIAZONIUM SALTS [J].
DELAMAR, M ;
HITMI, R ;
PINSON, J ;
SAVEANT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (14) :5883-5884
[4]   Covalent modification of carbon electrodes for voltammetric differentiation of dopamine and ascorbic acid [J].
Downard, AJ ;
Roddick, AD ;
Bond, AM .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :303-310
[5]   PROTEIN ADSORPTION AT GLASSY-CARBON ELECTRODES - THE EFFECT OF COVALENTLY BOUND SURFACE GROUPS [J].
DOWNARD, AJ ;
RODDICK, AD .
ELECTROANALYSIS, 1995, 7 (04) :376-378
[6]  
DOWNARD AJ, 1994, ELECTROANAL, V6, P397
[7]  
DOWNARD AJ, UNPUB
[8]   ACIDITY DETERMINATION IN DROPLETS FORMED BY ELECTROSPRAYING METHANOL-WATER SOLUTIONS [J].
GATLIN, CL ;
TURECEK, F .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :712-718
[9]   Use of poly(ester-sulfonic acid) film-coated electrodes as amperometric detectors in flow injection analysis [J].
Gennett, T ;
Rusin, WR ;
Gier, LM .
TALANTA, 1995, 42 (12) :2073-2078
[10]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595