Endothelial, cardiac muscle and skeletal muscle exhibit different viscous and elastic properties as determined by atomic force microscopy

被引:457
作者
Mathur, AB
Collinsworth, AM
Reichert, WM
Kraus, WE
Truskey, GA
机构
[1] Duke Univ, Dept Biomed Engn, Ctr Cellular & Biosurface Engn, Durham, NC 27708 USA
[2] Duke Univ, Dept Med, Div Cardiol, Durham, NC 27708 USA
[3] Duke Univ, Dept Cell Biol, Div Cardiol, Durham, NC 27708 USA
关键词
elastic modulus; mechanical properties; hysteresis; indenter geometry; probe velocity;
D O I
10.1016/S0021-9290(01)00149-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study evaluated the hypothesis that, due to functional and structural differences, the apparent elastic modulus and viscous behavior of cardiac and skeletal muscle and vascular endothelium would differ. To accurately determine the elastic modulus, the contribution of probe velocity, indentation depth., and the assumed shape of the probe were examined. Hysteresis was observed at high indentation velocities arising from viscous effects. Irreversible deformation was not observed for endothelial cells and hysteresis was negligible below 1 mum/s. For skeletal muscle and cardiac muscle cells, hysteresis was negligible below 0.25 mum/s. Viscous dissipation for endothelial and cardiac muscle cells was higher than for skeletal muscle cells. The calculated elastic modulus was most sensitive to the assumed probe geometry for the first 60 nm of indentation for the three cell types, Modeling the probe as a blunt cone-spherical cap resulted in variation in elastic modulus with indentation depth that was less than that calculated by treating the probe as a conical tip. Substrate contributions were negligible since the elastic modulus reached a steady value for indentations above 60 nm and the probe never indented more than 10% of the cell thickness. Cardiac cells were the stiffest (100.3 +/- 10.7 kPa), the skeletal muscle cells were intermediate (24.7 +/- 3.5 kPa), and the endothelial cells were the softest with a range of elastic moduli (1.4 +/- 0.1 to 6.8 +/- 0.4 kPa) depending on the location of the cell surface tested. Cardiac and skeletal muscle exhibited nonlinear elastic behavior. These passive mechanical properties are generally consistent with the function of these different cell types. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1545 / 1553
页数:9
相关论文
共 26 条
[21]   Cytoindentation for obtaining cell biomechanical properties [J].
Shin, D ;
Athanasiou, K .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (06) :880-890
[22]   DYNAMIC MICROMECHANICAL PROPERTIES OF CULTURED RAT ATRIAL MYOCYTES MEASURED BY ATOMIC-FORCE MICROSCOPY [J].
SHROFF, SG ;
SANER, DR ;
LAL, R .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1995, 269 (01) :C286-C292
[23]   Cytoskeletal mechanics in pressure-overload cardiac hypertrophy [J].
Tagawa, H ;
Wang, N ;
Narishige, T ;
Ingber, DE ;
Zile, MR ;
Cooper, G .
CIRCULATION RESEARCH, 1997, 80 (02) :281-289
[24]  
Weisenhorn A. L., 1993, Nanotechnology, V4, P106, DOI 10.1088/0957-4484/4/2/006
[25]   Method for isolation of adult mouse cardiac myocytes for studies of contraction and microfluorimetry [J].
Wolska, BM ;
Solaro, RJ .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (03) :H1250-H1255
[26]   SERIAL PASSING AND DIFFERENTIATION OF MYOGENIC CELLS ISOLATED FROM DYSTROPHIC MOUSE MUSCLE [J].
YAFFE, D ;
SAXEL, O .
NATURE, 1977, 270 (5639) :725-727