Determination of iron(II) and total iron in environmental water samples by flow injection analysis with column preconcentration of chelating resin functionalized with N-hydroxyethylethylenediamine ligands and chemiluminescence detection

被引:83
作者
Hirata, S
Yoshihara, H
Aihara, M
机构
[1] Chugoku Natl Ind Inst, Hiroshima 7370197, Japan
[2] Kinki Univ, Higashihiroshima 7392116, Japan
关键词
flow injection analysis; amberlite XAD-4-HEED column; Fe(II); environmental water samples;
D O I
10.1016/S0039-9140(99)00061-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis (FIA) technique for the determination of Fe(II) and total-Fe in environmental water samples has been developed with a high sensitivity. The resin used for preconcentration of iron was the macroporous resin, Amberlite XAD-4 functionalized by N-hydroxyethylethylenediamine (HEED) groups. The technique employed was FIA by combination of on-line chelate resin preconcentration and chemiluminescence detection (CL), using brilliant sulfoflavine and hydrogen peroxide reagent solutions. The interference by coexisting Fe(III) could be eliminated by addition of 1 x 10(-6) mol of deferrioxamine B solution. The detection limits of Fe(II) and total-Fe were 0.80 and 0.36 nmol l(-1) for 5.6-ml seawater samples with a concentration of 2 nmol l(-1). The relative standard deviations for both samples were less than +/- 4%. A typical analysis for Fe(II) can be performed in 7.5 min. The technique was ascertained by comparing the analytical value of total-Fe with the certified value of Fe in the reference standard seawater CASS-3. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1059 / 1067
页数:9
相关论文
共 29 条
[1]   SYNTHESIS, CHARACTERIZATION AND METAL SORPTION STUDIES OF A CHELATING RESIN FUNCTIONALIZED WITH N-HYDROXYETHYLETHYLENEDIAMINE LIGANDS [J].
DEV, K ;
RAO, GN .
ANALYST, 1995, 120 (10) :2509-2512
[2]   DETERMINATION OF SUBNANOMOLAR LEVELS OF IRON(II) AND TOTAL DISSOLVED IRON IN SEAWATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ELROD, VA ;
JOHNSON, KS ;
COALE, KH .
ANALYTICAL CHEMISTRY, 1991, 63 (09) :893-898
[3]   CHARACTERIZATION OF CALCIUM FORM OF CHELEX-100 FOR TRACE-METAL STUDIES [J].
FIGURA, P ;
MCDUFFIE, B .
ANALYTICAL CHEMISTRY, 1977, 49 (13) :1950-1953
[4]  
Hirata S, 1996, FRESEN J ANAL CHEM, V355, P676
[5]   PRECONCENTRATION OF CHROMIUM(III) AND CHROMIUM(VI) IN SEA-WATER BY COMPLEXATION WITH QUINOLIN-8-OL AND ADSORPTION ON MACROPOROUS RESIN [J].
ISSHIKI, K ;
SOHRIN, Y ;
KARATANI, H ;
NAKAYAMA, E .
ANALYTICA CHIMICA ACTA, 1989, 224 (01) :55-64
[6]  
JHONSON KS, 1994, MAR CHEM, V46, P319
[7]   SPECTROPHOTOMETRIC DETERMINATION OF IRON(II) IN SEAWATER AT NANOMOLAR CONCENTRATIONS [J].
KING, DW ;
LIN, J ;
KESTER, DR .
ANALYTICA CHIMICA ACTA, 1991, 247 (01) :125-132
[8]   PHOTO-REDUCTION OF FE (III) BY DISSOLVED ORGANIC-SUBSTANCES AND EXISTENCE OF FE (II) IN SEAWATER DURING SPRING BLOOMS [J].
KUMA, K ;
NAKABAYASHI, S ;
SUZUKI, Y ;
KUDO, I ;
MATSUNAGA, K .
MARINE CHEMISTRY, 1992, 37 (1-2) :15-27
[9]   VINYL POLYMER AGGLOMERATE BASED TRANSITION-METAL CATION CHELATING ION-EXCHANGE RESIN CONTAINING THE 8-HYDROXYQUINOLINE FUNCTIONAL-GROUP [J].
LANDING, WM ;
HARALDSSON, C ;
PAXEUS, N .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3031-3035
[10]  
Lyman J, 1940, J MAR RES, V3, P134