Microinfusion using hollow microneedles

被引:189
作者
Martanto, W
Moore, JS
Kashlan, O
Kamath, R
Wang, PM
O'Neal, JM
Prausnitz, MR [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Ctr Drug Design Dev & Delivery, Atlanta, GA 30332 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
hyaluronidase; infusion; MEMS; skin; transdermal drug delivery;
D O I
10.1007/s11095-005-8498-8
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. The aim of the study is to determine the effect of experimental parameters on microinfusion through hollow microneedles into skin to optimize drug delivery protocols and identify rate-limiting barriers to flow. Methods. Glass microneedles were inserted to a depth of 720-1080 mu m into human cadaver skin to microinfuse sulforhodamine solution at constant pressure. Flow rate was determined as a function of experimental parameters, such as microneedle insertion and retraction distance, infusion pressure, microneedle tip geometry, presence of hyaluronidase, and time. Results. Single microneedles inserted into skin without retraction were able to infuse sulforhodamine solution into the skin at flow rates of 15-96 mu l/h. Partial retraction of microneedles increased flow rate up to 11.6-fold. Infusion flow rate was also increased by greater insertion depth, larger infusion pressure, use of a beveled microneedle tip, and the presence of hyaluronidase such that flow rates ranging from 21 to 1130 mu l/h were achieved. These effects can be explained by removing or overcoming the large flow resistance imposed by dense dermal tissue, compressed during microneedle insertion, which blocks flow from the needle tip. Conclusions. By partially retracting microneedles after insertion and other methods to overcome flow resistance of dense dermal tissue, protocols can be designed for hollow microneedles to microinfuse fluid at therapeutically relevant rates.
引用
收藏
页码:104 / 113
页数:10
相关论文
共 40 条
[1]  
Bancroft J.D., 2002, THEORY PRACTICE HIST, V5th
[2]   Diabetes management in the new millennium using insulin pump therapy [J].
Bode, BW ;
Sabbah, HT ;
Gross, TM ;
Fredrickson, LP ;
Davidson, PC .
DIABETES-METABOLISM RESEARCH AND REVIEWS, 2002, 18 :S14-S20
[3]   A randomized controlled trial of local injections of hyaluronidase versus placebo in cancer patients receiving subcutaneous hydration [J].
Bruera, E ;
Neumann, CM ;
Pituskin, E ;
Calder, K ;
Hanson, J .
ANNALS OF ONCOLOGY, 1999, 10 (10) :1255-1258
[4]   Microfabricated silicon microneedles for nonviral cutaneous gene delivery [J].
Chabri, F ;
Bouris, K ;
Jones, T ;
Barrow, D ;
Hann, A ;
Allender, C ;
Brain, K ;
Birchall, J .
BRITISH JOURNAL OF DERMATOLOGY, 2004, 150 (05) :869-877
[5]   A multichannel neural probe for selective chemical delivery at the cellular level [J].
Chen, JK ;
Wise, KD ;
Hetke, JF ;
Bledsoe, SC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (08) :760-769
[6]  
Colquitt JL, 2004, HEALTH TECHNOL ASSES, V8, P1
[7]   Transdermal delivery of desmopressin using a coated microneedle array patch system [J].
Cormier, M ;
Johnson, B ;
Ameri, M ;
Nyam, K ;
Libiran, L ;
Zhang, DD ;
Daddona, P .
JOURNAL OF CONTROLLED RELEASE, 2004, 97 (03) :503-511
[8]  
CORMIER M, 2003, MODIFIED RELEASE DRU, P589
[9]   Hollow metal microneedles for insulin delivery to diabetic rats [J].
Davis, SP ;
Martanto, W ;
Allen, MG ;
Prausnitz, MR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (05) :909-915
[10]   ABC of labour care - Relief of pain [J].
Findley, I ;
Chamberlain, G .
BRITISH MEDICAL JOURNAL, 1999, 318 (7188) :927-930