The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components

被引:44
作者
Kurtz, SM
Edidin, AA
Bartel, DL
机构
[1] CORNELL UNIV,SIBLEY SCH MECH & AEROSP ENGN,ITHACA,NY 14853
[2] OSTEON,R&D CORP,ALLENDALE,MI
关键词
contact stress; metal backing; acetabular component; polishing; cup orientation;
D O I
10.1016/S0021-9290(96)00181-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Mechanical interactions between the polyethylene liner and the metal-backing play an important role in the load transfer and debris-generation mechanisms of an acetabular component. Insert thickness, cup orientation, and insert-shell interface conditions affect the resulting contact stresses at the articulating and backside surfaces of the polyethylene component. The objective of this study was to determine the variation in contact stresses on a hemispherical acetabular component as a function of the friction coefficient of the liner-shell interface, the thickness of the insert, and the load application angle. Three-dimensional finite element models of a metal-backed acetabular component with liner thicknesses of 3-12 mm were developed. The insert-shell interface was modeled as either matte or highly polished, and the load angle of the joint reaction force was changed from 36 to 63 degrees with respect to the dome. We found that the contact stresses at the articulating and backside surfaces of the insert were relatively insensitive to changes in the coefficient of friction at the insert-shell interface (resulting in similar to 1-10% variation in contact stress), when compared to the effect of changing the insert's thickness (similar to 80% variation in contact stress) or changing the direction of the joint reaction force (similar to 20% variation in contact stress). The results of this study suggest that polishing the metal at the insert-shell interface does not substantially change the contact stresses at either surface of the component. Of the design variables available for selective modification by either the surgeon or the engineer, insert thickness and shell orientation play a greater role in determining the magnitude of the resulting contact stresses. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:639 / 642
页数:4
相关论文
共 28 条
[1]
THE EFFECT OF CONFORMITY AND PLASTIC THICKNESS ON CONTACT STRESSES IN METAL-BACKED PLASTIC IMPLANTS [J].
BARTEL, DL ;
BURSTEIN, AH ;
TODA, MD ;
EDWARDS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :193-199
[2]
Carter D R, 1983, Hip, P216
[3]
POLYETHYLENE WEAR IN CEMENTED METAL-BACKED ACETABULAR CUPS [J].
CATES, HE ;
FARIS, PM ;
KEATING, EM ;
RITTER, MA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :249-253
[4]
COLLIER JP, 1992, CLIN ORTHOP RELAT R, V285, P129
[5]
COLLIER JP, 1990, CLIN ORTHOP RELAT R, V261, P107
[6]
Crowninshield R D, 1983, Hip, P207
[7]
DALSTRA M, 1993, T 39 ORTH RES SOC, P442
[8]
DALSTRA M, 1991, 37TH P ANN M ORTH RE, P272
[9]
GABRIELS M, 1992, T 38 ORTHOP RES SOC, P47
[10]
GONZALEZ MH, 1988, CLIN ORTHOP RELAT R, V232, P156