Evaluation of perfusion and viability in hypothermic non-beating isolated porcine hearts using cardiac MRI

被引:4
作者
Rivard, AL
Swingen, CM
Gallegos, RP
Gatlin, DL
Jerosch-Herold, M
John, R
Bianco, RW
机构
[1] Univ Minnesota, Dept Physiol, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Radiol, Minneapolis, MN 55455 USA
[3] Oregon Hlth & Sci Univ, Adv Imaging Res Ctr, Portland, OR 97239 USA
[4] Univ Minnesota, Dept Surg, Div Cardiovasc & Thorac Surg, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Dept Surg, Expt Surg Serv, Minneapolis, MN 55455 USA
关键词
heart; hypothermic storage; Magnetic Resonance Imaging; perfusion; porcine;
D O I
10.1007/s10554-005-9015-1
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The donor heart undergoes degradation during hypothermic storage. An assessment of donor heart preservation is typically done with histological or biochemical methods that are not feasible in the clinical setting. We describe a method to study the donor heart using cardiac perfusion MRI that is potentially feasible for clinical use. Standard cardiectomy was performed in the pig model and the hearts were stored in normal saline at 5 degrees C. Imaging was performed by using a rapid gradient-echo sequence (FLASH) with saturation-recovery preparation for T1-weighting in the short axis and horizontal long axis views. Approximately 80 serial images were acquired at a rate of 1/s during administration of 0.006 mmol/ml Gd-DTPA (500 ml, 1 l/min). Signal intensity vs. time curves were generated for each heart and slice imaged and compared to a 0.006 mmol/ml Gd-DTPA reference. H&E stained biopsies of the LV, RV, and septum were also obtained. The mean duration of heart storage (N=10) was 8.8 h (range 4.2-19.2 h). Histologically, no differences were seen in H&E stained biopsies among hearts at different storage times. However cardiac MRI revealed a decrease in perfusion units in each subsequent heart tested after 4.2 h. (R=0.49). Average peak up-slope was used as a surrogate measure for flow capacity through the microvasculature and peak contrast enhancement was used as a measurement of viable microvasculature. The 4 h heart had 83% peak contrast enhancement of the reference standard, as compared to 44% for the 19.2 h heart. The decrease in peak enhancement is directly related to the duration of storage time. No correlation of peak up-slope of the intensity curve to storage time was found. This new application of cardiac MRI in the donor heart is applicable to: (1) assessing marginal hearts, (2) evaluating donor heart preservation techniques, and (3) correlating pre- to post-transplant viability.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 26 条
[1]
MAGNETIC-RESONANCE-IMAGING OF CARDIAC TRANSPLANTS - THE EVALUATION OF REJECTION OF CARDIAC ALLOGRAFTS WITH AND WITHOUT IMMUNOSUPPRESSION [J].
AHERNE, T ;
TSCHOLAKOFF, D ;
FINKBEINER, W ;
SECHTEM, U ;
DERUGIN, N ;
YEE, E ;
HIGGINS, CB .
CIRCULATION, 1986, 74 (01) :145-156
[2]
Utility of cardiac magnetic resonance imaging for the diagnosis of heart transplant rejection [J].
Almenar, L ;
Igual, B ;
Martínez-Dolz, L ;
Arnau, MA ;
Osa, A ;
Rueda, J ;
Palencia, M .
TRANSPLANTATION PROCEEDINGS, 2003, 35 (05) :1962-1964
[3]
Function of adult pig hearts after 2 and 12 hours of cold cardioplegic preservation [J].
Budrikis, A ;
Bolys, R ;
Liao, QM ;
Ingemansson, R ;
Sjöberg, T ;
Steen, S .
ANNALS OF THORACIC SURGERY, 1998, 66 (01) :73-78
[4]
Isolated four-chamber working swine heart model [J].
Chinchoy, E ;
Soule, CL ;
Houlton, AJ ;
Gallagher, WJ ;
Hjelle, MA ;
Laske, TG ;
Morissette, J ;
Iaizzo, PA .
ANNALS OF THORACIC SURGERY, 2000, 70 (05) :1607-1614
[5]
DARRACOTTCANKOVIC S, 1987, J THORAC CARDIOV SUR, V93, P95
[6]
MR IMAGING IN ASSESSMENT OF CARDIAC TRANSPLANT REJECTION IN HUMANS [J].
DOORNBOS, J ;
VERWEY, H ;
ESSED, CE ;
BALK, AHMM ;
DEROOS, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (01) :77-81
[7]
Dyszkiewicz W, 1990, Mater Med Pol, V22, P147
[8]
FERRANS VJ, 1970, CIRCULATION, V41, pI104
[9]
Flameng W, 1988, Eur J Cardiothorac Surg, V2, P244, DOI 10.1016/1010-7940(88)90079-6
[10]
SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89