Human MCG measurements with a high-sensitivity potassium atomic magnetometer

被引:46
作者
Kamada, K. [1 ]
Ito, Y. [1 ,2 ]
Kobayashi, T. [1 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto 6158510, Japan
[2] Kyoto Univ, Ctr Promot Interdisciplinary Educ & Res, Adv Biomed Engn Res Unit, Kyoto 6068501, Japan
关键词
atomic magnetometer; biomagnetic measurement; magnetocardiograms (MCGs);
D O I
10.1088/0967-3334/33/6/1063
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Measuring biomagnetic fields, such as magnetocardiograms (MCGs), is important for investigating biological functions. To address to this need, we developed an optically pumped atomic magnetometer. In this study, human MCGs were acquired using a potassium atomic magnetometer without any modulating systems. The sensitivity of the magnetometer is comparable to that of high-T-c superconducting quantum interference devices (SQUIDs) and is sufficient for acquiring human MCGs. The activity of a human heart estimated from the MCG maps agrees well with that measured with SQUID magnetometers. Thus, our magnetometer produces reliable results, which demonstrate the potential of our atomic magnetometer for biomagnetic measurements.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 22 条
[1]   A 75-ch SQUID biomagnetometer system for human cervical spinal cord evoked field [J].
Adachi, Yoshiaki ;
Kawai, Jun ;
Uehara, Gen ;
Miyamoto, Masakazu ;
Tomizawa, Shoji ;
Kawabata, Shigenori .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (04) :3867-3873
[2]   High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation [J].
Allred, JC ;
Lyman, RN ;
Kornack, TW ;
Romalis, MV .
PHYSICAL REVIEW LETTERS, 2002, 89 (13) :130801-130801
[3]   Cesium coherent population trapping magnetometer for cardiosignal detection in an unshielded environment [J].
Belfi, J. ;
Bevilacqua, G. ;
Biancalana, V. ;
Cartaleva, S. ;
Dancheva, Y. ;
Moi, L. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2007, 24 (09) :2357-2362
[4]   A laser-pumped magnetometer for the mapping of human cardiomagnetic fields [J].
Bison, G ;
Wynands, R ;
Weis, A .
APPLIED PHYSICS B-LASERS AND OPTICS, 2003, 76 (03) :325-328
[5]   A room temperature 19-channel magnetic field mapping device for cardiac signals [J].
Bison, G. ;
Castagna, N. ;
Hofer, A. ;
Knowles, P. ;
Schenker, J. -L. ;
Kasprzak, M. ;
Saudan, H. ;
Weis, A. .
APPLIED PHYSICS LETTERS, 2009, 95 (17)
[6]   Optical magnetometry [J].
Budker, Dmitry ;
Romalis, Michael .
NATURE PHYSICS, 2007, 3 (04) :227-234
[7]   A high-sensitivity laser-pumped Mx magnetometer [J].
Groeger, S ;
Bison, G ;
Schenker, JL ;
Wynands, R ;
Weis, A .
EUROPEAN PHYSICAL JOURNAL D, 2006, 38 (02) :239-247
[8]   MAGNETOENCEPHALOGRAPHY - THEORY, INSTRUMENTATION, AND APPLICATIONS TO NONINVASIVE STUDIES OF THE WORKING HUMAN BRAIN [J].
HAMALAINEN, M ;
HARI, R ;
ILMONIEMI, RJ ;
KNUUTILA, J ;
LOUNASMAA, OV .
REVIEWS OF MODERN PHYSICS, 1993, 65 (02) :413-497
[9]   SPIN-EXCHANGE SHIFT AND NARROWING OF MAGNETIC-RESONANCE LINES IN OPTICALLY PUMPED ALKALI VAPORS [J].
HAPPER, W ;
TANG, H .
PHYSICAL REVIEW LETTERS, 1973, 31 (05) :273-276
[10]   Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium [J].
Ito, Yosuke ;
Ohnishi, Hiroyuki ;
Kamada, Keigo ;
Kobayashi, Tetsuo .
IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (10) :3550-3553