Performance assessments of diagnostic systems under the FROC paradigm: Experimental, analytical, and results interpretation issues

被引:22
作者
Gur, David [1 ]
Rockette, Howard E. [2 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Radiol, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Grad Sch Publ Hlth, Dept Biostat, Pittsburgh, PA 15261 USA
关键词
detection; diagnosis; technology assessment; observer performance; FROC;
D O I
10.1016/j.acra.2008.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As use of free response receiver-operating characteristic (FROC) curves gains more acceptance for quantitatively assessing the performance of diagnostic systems, it is important that the experimentalist understands the possible role of this approach as one of the experimental design paradigms that are available to him or her among all other approaches as well as some of the issues associated with FROC type studies. In a number of experimental scenarios, the FROC paradigm and associated analytical tools have theoretical and practical advantages over both the binary and the ROC approaches to performance assessments of diagnostic systems, but it also has some limitations related to experimental design, data analyses, clinical relevance, and complexity in the interpretation of the results. These issues are rarely discussed and are the focus of this work.
引用
收藏
页码:1312 / 1315
页数:4
相关论文
共 18 条
[1]  
BANDOS AI, 2008, BIOMETRICS
[2]   ROC curves predicted by a model of visual search [J].
Chakraborty, D. P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :3463-3482
[3]   A search model and figure of merit for observer data acquired according to the free-response paradigm [J].
Chakraborty, D. P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :3449-3462
[4]   Spatial localization accuracy of radiologists in free-response studies: Inferring perceptual FROC curves from mark-rating data [J].
Chakraborty, Dev ;
Yoon, Hong-Jun ;
Mello-Thoms, Claudia .
ACADEMIC RADIOLOGY, 2007, 14 (01) :4-18
[5]   Observer studies involving detection and localization: Modeling, analysis, and validation [J].
Chakraborty, DP ;
Berbaum, KS .
MEDICAL PHYSICS, 2004, 31 (08) :2313-2330
[6]   Maximum likelihood fitting of FROC curves under an initial-detection-and-candidate-analysis model [J].
Edwards, DC ;
Kupinski, MA ;
Metz, CE ;
Nishikawa, RM .
MEDICAL PHYSICS, 2002, 29 (12) :2861-2870
[7]  
GUR D, RADIOLOGY IN PRESS
[8]   Power estimation for the Dorfman-Berbaum-Metz method [J].
Hillis, SL ;
Berbaum, KS .
ACADEMIC RADIOLOGY, 2004, 11 (11) :1260-1273
[9]   Anniversary paper: Evaluation of medical imaging systems [J].
Krupinski, Elizabeth A. ;
Jiang, Yulei .
MEDICAL PHYSICS, 2008, 35 (02) :645-659
[10]   MULTIREADER RECEIVER OPERATING CHARACTERISTIC STUDIES - A COMPARISON OF STUDY DESIGNS [J].
OBUCHOWSKI, NA .
ACADEMIC RADIOLOGY, 1995, 2 (08) :709-716