Soil and litter phosphorus-31 nuclear magnetic resonance spectroscopy: Extractants, metals, and phosphorus relaxation times

被引:127
作者
Cade-Menun, BJ
Liu, CW
Nunlist, R
McColl, JG
机构
[1] Univ Calif Berkeley, Dept Environm Sci Policy & Management, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Coll Chem, Berkeley, CA 94720 USA
[3] Stanford Univ, Stanford Magnet Resonance Lab, Stanford, CA 94305 USA
关键词
D O I
10.2134/jeq2002.0457
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Phosphorus-31 nuclear magnetic resonance (NMR) spectroscopy is an excellent tool with which to study soil organic P, allowing quantitative, comparative analysis of P forms. However, for P-31 NMR to be tative, all peaks must be completely visible, and in their correct relative proportions. There must be no line broadening, and adequate delay times must be used to avoid saturation of peaks. The objective of this study was to examine the effects of extractants on delay times and peak saturation. Two samples (a forest litter and a mineral soil sample) and three extractants (0.25 M NaOH, NaOH plus Chelex (Bio-Rad Laboratories, Hercules, CA), and NaOH plus EDTA) were used to determine the differences in the concentration of P and cations solubilized by each extractant, and to measure spin-lattice (T-1) relaxation times of P peaks in each extract. For both soil and litter, NaOH-Chelex extracted the lowest concentrations of P. For the litter sample, T-1 values were short for all extractants due to the high Fe concentration remaining after extraction. For the soil sample, there were noticeable differences among the extractants. The NaOH-Chelex sample had less Fe and Mn remaining in solution after extraction than the other extractants, and the longest delay times used in the study, 6.4 s, were not long enough for quantitative analysis. Delay times of 1.5 to 2 s for the NaOH and NaOH-EDTA were adequate. Line broadening was highest in the NaOH extracts, which had the highest concentration of Fe. On the basis of these results, recommendations for future analyses of soil and litter samples by solution IT NMR spectroscopy include: careful selection of an extractant; measurement of paramagnetic ions extracted with P; use of appropriate delay times and the minimum number of scans; and measurement of T-1 values whenever possible.
引用
收藏
页码:457 / 465
页数:9
相关论文
共 43 条
[41]  
Wilson M., 1987, NMR TECHNIQUES APPL, DOI DOI 10.1016/B978-0-08-034852-0.50007-4
[42]  
ZECH W, 1985, Z PFLANZ BODENKUNDE, V148, P626, DOI 10.1002/jpln.19851480605
[43]  
ZECH W, 1987, Z PFLANZENERNAEHR BO, V156, P61