ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation

被引:59
作者
Harkewicz, R [1 ]
Belov, ME [1 ]
Anderson, GA [1 ]
Pasa-Tolic, L [1 ]
Masselon, CD [1 ]
Prior, DC [1 ]
Udseth, HR [1 ]
Smith, RD [1 ]
机构
[1] Pacific NE Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
基金
美国能源部;
关键词
D O I
10.1016/S1044-0305(01)00343-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Data-dependent external m/z selection and accumulation of ions is demonstrated in use with ESI-FTICR instrumentation, with two different methods for ion selection being explored. One method uses RF/DC quadrupole filtering and is described in use with an 11.5 tesla (T) FTICR instrument, while the second method employs RF-only resonance dipolar excitation selection and is described in use with a 3.5 T FTICR instrument. In both methods ions are data-dependently selected on the fly in a linear quadrupole ion guide, then accumulated in a second linear RF-only quadrupole trap that immediately follows. A major benefit of ion preselection prior to external accumulation is the enhancement of ion populations for low-level species. This development is expected to expand the dynamic range and sensitivity of FTICR for applications including analysis of complex polypeptide mixtures (e.g., proteomics).
引用
收藏
页码:144 / 154
页数:11
相关论文
共 36 条
[1]   METAL CLUSTER ION-CYCLOTRON RESONANCE - COMBINING SUPERSONIC METAL CLUSTER BEAM TECHNOLOGY WITH FT-ICR [J].
ALFORD, JM ;
WILLIAMS, PE ;
TREVOR, DJ ;
SMALLEY, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1986, 72 (1-2) :33-51
[2]  
ANDERSON GA, 1995, P 43 ANN C MASS SPEC, P1093
[3]  
Belov ME, 2000, J AM SOC MASS SPECTR, V11, P19, DOI 10.1016/S1044-0305(99)00121-X
[4]   Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins [J].
Belov, ME ;
Gorshkov, MV ;
Udseth, HR ;
Anderson, GA ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2271-2279
[5]   Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization [J].
Belov, ME ;
Anderson, GA ;
Angell, NH ;
Shen, YF ;
Tolic, N ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5052-5060
[6]   A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Belov, ME ;
Nikolaev, EN ;
Alving, K ;
Smith, RD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1172-1180
[7]   Ion discrimination during ion accumulation in a quadrupole interface external to a Fourier transform ion cyclotron resonance mass spectrometer [J].
Belov, ME ;
Nikolaev, EN ;
Harkewicz, R ;
Masselon, CD ;
Alving, K ;
Smith, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 208 (1-3) :205-225
[8]   Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity [J].
Belov, ME ;
Nikolaev, EN ;
Anderson, GA ;
Auberry, KJ ;
Harkewicz, R ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) :38-48
[9]  
BERG C, 1998, P 46 ASMS C MASS SPE, P515
[10]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192