Coronary stent grafts covered by a polytetrafluoroethylene membrane

被引:100
作者
Elsner, M [1 ]
Auch-Schwelk, W [1 ]
Britten, M [1 ]
Walter, DH [1 ]
Schächinger, V [1 ]
Zeiher, AM [1 ]
机构
[1] JW Goethe Univ, Dept Cariol, Med Klin 4, Frankfurt, Germany
关键词
D O I
10.1016/S0002-9149(99)00289-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In a prospective observational study, 40 patients were treated with coronary stent grafts covered by a polytetrafluoroethylene membrane. These devices may be regarded as therapy of choice for acute coronary rupture; treatment of conventional in-stent restenosis was not associated with a favorable outcome, whereas the promising results in degenerated vein grafts warrrant a randomized, controlled trial.
引用
收藏
页码:335 / +
页数:5
相关论文
共 21 条
[1]   Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis [J].
Dauerman, HL ;
Baim, DS ;
Cutlip, D ;
Sparano, AM ;
Gibson, CM ;
Kuntz, RE ;
Carrozza, JP ;
Garber, GR ;
Cohen, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) :277-284
[2]   BALLOON ANGIOPLASTY FOR THE TREATMENT OF LESIONS IN SAPHENOUS-VEIN BYPASS GRAFTS [J].
DEFEYTER, PIMJ ;
VANSUYLEN, RJ ;
DEJAEGERE, PPT ;
TOPOL, EJ ;
SERRUYS, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1539-1549
[3]   Patency and tissue response related to two types of polytetrafluoroethylene-covered stents in the dog [J].
Dolmatch, BL ;
Tio, FO ;
Li, XD ;
Dong, YH .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (05) :641-649
[4]   Perforation and rupture of coronary arteries [J].
Elsner, M ;
Zeiher, AM .
HERZ, 1998, 23 (05) :311-318
[5]  
Elsner M, 1996, CATHETER CARDIO DIAG, V39, P271
[6]   Long-term follow-up of a high risk cohort after stent implantation in saphenous vein grafts [J].
Frimerman, A ;
Rechavia, E ;
Eigler, N ;
Payton, MR ;
Makkar, R ;
Litvack, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (05) :1277-1283
[7]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[8]   BALLOON ANGIOPLASTY FOR TREATMENT OF IN-STENT RESTENOSIS - FEASIBILITY, SAFETY, AND EFFICACY [J].
MACANDER, PJ ;
ROUBIN, GS ;
AGRAWAL, SK ;
CANNON, AD ;
DEAN, LS ;
BAXLEY, WA .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (02) :125-131
[9]   Effect of polytetrafluoroethylene covering of Palmaz stents on the development of intimal hyperplasia in human iliac arteries [J].
Marin, ML ;
Veith, FJ ;
Cynamon, J ;
Parsons, RE ;
Lyon, RT ;
Suggs, WD ;
Bakal, CW ;
Waahl, S ;
Sanchez, LA ;
Yuan, JC ;
Ohki, T .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (05) :651-656
[10]   Aortocoronary bypass grafting with expanded polytetrafluoroethylene: 12-year patency [J].
McLarty, AJ ;
Phillips, MR ;
Holmes, DR ;
Schaff, HV .
ANNALS OF THORACIC SURGERY, 1998, 65 (05) :1442-1444