Determination of viable Escherichia coli using antibody-coated paramagnetic beads with fluorescence detection

被引:16
作者
Dudak, F. Ceyda [1 ]
Boyaci, Ismail H. [1 ]
Jurkevica, Agnese [2 ]
Hossain, Mahmud [2 ]
Aquilar, Zoraida [2 ]
Halsall, H. Brian [2 ]
Seliskar, Carl J. [2 ]
Heineman, William R. [2 ]
机构
[1] Hacettepe Univ, Dept Food Engn, TR-06532 Ankara, Turkey
[2] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
关键词
Escherichia coli; Immunoassay; Paramagnetic bead; beta-Galactosidase; Fluorescence; REAL-TIME PCR; IMMUNOMAGNETIC SEPARATION; BETA-GALACTOSIDASE; RAPID DETECTION; PATHOGENIC BACTERIA; TOTAL COLIFORMS; FLOW-CYTOMETRY; O157-H7; WATER; QUANTIFICATION;
D O I
10.1007/s00216-008-2531-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and convenient assay system was developed to detect viable Escherichia coli in water. The target bacteria were recovered from solution by immunomagnetic separation and incubated in tryptic soy broth with isopropyl-beta-D-thiogalactopyranoside, which induces formation of beta-galactosidase in viable bacteria. Lysozyme was used to lyse E. coli cells and release the beta-galactosidase. beta-Galactosidase converted 4-methylumbelliferyl-beta-D-galactoside to 4-methylumbelliferone (4-MU), which was measured by fluorescence spectrophotometry using excitation and emission wavelengths of 355 and 460 nm, respectively. Calibration graphs of 4-MU fluorescence intensity versus E. coli concentration showed a detection range between 8 x 104 and 1.6 x 10(7) cfu mL(-1), with a total analysis time of less than 3 h. The advantage of this method is that it detects viable cells because it is based on the activity of the enzyme intrinsic to live E. coli.
引用
收藏
页码:949 / 956
页数:8
相关论文
共 37 条
[1]   Coupling of enzymatic and immunoassay steps to detect E-coli:: a new, highly sensitive tandem technique for the analysis of low levels of bacteria [J].
Abuknesha, RA ;
Darwish, F .
TALANTA, 2005, 65 (02) :343-348
[2]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[3]   Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection [J].
Beyor, Nathaniel ;
Seo, Tae Seok ;
Liu, Peng ;
Mathies, Richard A. .
BIOMEDICAL MICRODEVICES, 2008, 10 (06) :909-917
[4]   Statistical modeling of β-galactosidase inhibition during lactose hydrolysis [J].
Boyaci, IH ;
Bas, D ;
Dudak, FC ;
Topçu, A ;
Saldamli, I ;
Seker, UÖS ;
Tamerler, C .
FOOD BIOTECHNOLOGY, 2006, 20 (01) :79-91
[5]   Amperometric determination of live Escherichia coli using antibody-coated paramagnetic beads [J].
Boyaci, IH ;
Aguilar, ZP ;
Hossain, M ;
Halsall, HB ;
Seliskar, CJ ;
Heineman, WR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (05) :1234-1241
[6]   NEW MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN WATER [J].
BRENNER, KP ;
RANKIN, CC ;
ROYBAL, YR ;
STELMA, GN ;
SCARPINO, PV ;
DUFOUR, AP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (11) :3534-3544
[7]   Method for assessment of functional affinity of antibodies for live bacteria [J].
Brovko, L ;
Young, D ;
Griffiths, MW .
JOURNAL OF MICROBIOLOGICAL METHODS, 2004, 58 (01) :49-57
[8]  
Burtis C., 1999, TIETZ TXB CLIN CHEM
[9]   Detection of pathogenic bacteria in food samples using highly-dispersed carbon particles [J].
Chemburu, S ;
Wilkins, E ;
Abdel-Hamid, I .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) :491-499
[10]   Sequence of the Escherichia coli O26O antigen gene cluster and identification of O26 specific genes [J].
D'Souza, JA ;
Wang, L ;
Reeves, P .
GENE, 2002, 297 (1-2) :123-127