Voltammetric determination of chloramphenicol in milk at electrochemically activated carbon fibre microelectrodes

被引:94
作者
Agüí, L [1 ]
Guzmán, A [1 ]
Yáñez-Sedeño, P [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
chloramphenicol; electrochemically activated carbon fibres; microelectrodes;
D O I
10.1016/S0003-2670(02)00245-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical activation of cylindrical carbon fibre microelectrodes (CFMEs) by repetitive square-wave (SW) voltammetric scans between 0.0 and +2.6 V has shown to increase dramatically the cathodic current of chloramphenicol (CAP). This is attributed to the increase of the carbon fibre surface area due to its fracture and the appearance of deep fissures along the main fibre axis. Cyclic voltammograms of CAP suggested a contribution to the total current from most likely thin-layer electrolysis. The current density: concentration ratio calculated for the reduction of CAP at an activated fibre was 6.5 x 10(7) muA cm(-2) mol(-1) l. A method for the determination of CAP at low concentrations levels, using SW voltammetry at electrochemically activated cylindrical microelectrodes, was developed. Different chemical and electrochemical variables involved in the activation step were optimised. Calibration graphs were linear (r = 0.9990) in the 1.0 x 10(-7) to 1.0 x 10(-5) mol l(-1) concentration range, with a slope of (2.69 + 0.03) x 10(5) muA mol(-1) l. A limit of detection of 4.7 x 10(-8) mol l(-1) (15 ng ml(-1)) was found. The SWV method was applied for the determination of CAP in milk samples spiked with the antibiotic at two concentration levels: 64 and 320 ng ml(-1). Recoveries >97% were obtained in all cases by following a very simple experimental procedure. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 27 条
  • [1] Abjean JP, 1997, J AOAC INT, V80, P737
  • [2] Agui L, 1996, J ELECTROANAL CHEM, V414, P141
  • [3] ANALYTICAL APPLICATIONS OF CYLINDRICAL CARBON-FIBER MICROELECTRODES - SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANTS IN FOOD
    AGUI, ML
    REVIEJO, AJ
    YANEZSEDENO, P
    PINGARRON, JM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (13) : 2195 - 2200
  • [4] GAS-CHROMATOGRAPHIC DETERMINATION OF INCURRED CHLORAMPHENICOL RESIDUES IN EGGS FOLLOWING OPTIMAL EXTRACTION
    AKHTAR, MH
    DANIS, C
    SAUVE, A
    BARRY, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (01) : 123 - 130
  • [5] VOLTAMMETRY AT MICROCYLINDER ELECTRODES .1. LINEAR SWEEP VOLTAMMETRY
    AOKI, K
    HONDA, K
    TOKUDA, K
    MATSUDA, H
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (02): : 267 - 279
  • [6] BENSENHARD JO, 1983, ANGE CHEM INT ED ENG, V22, P950
  • [7] Borner S, 1995, J AOAC INT, V78, P1153
  • [8] Nanostructured carbon fiber disk electrodes for sensitive determinations of adenosine and uric acid
    Brajter-Toth, A
    Abou El-Nour, K
    Cavalheiro, ET
    Bravo, R
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (07) : 1576 - 1584
  • [9] HPLC DETERMINATION OF CHLORAMPHENICOL AND THIAMPHENICOL RESIDUES IN GAMEBIRD MEATS
    DIPIETRA, AM
    PIAZZA, V
    ANDRISANO, V
    CAVRINI, V
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (17): : 3529 - 3543
  • [10] Determination of chloramphenicol (CAP) in food products by differential pulse polarography
    Duda, J
    Kucharska, U
    [J]. ANALYTICAL LETTERS, 1999, 32 (05) : 1049 - 1064