Slow fluorescent indicators of membrane potential: A survey of different approaches to probe response analysis

被引:127
作者
Plasek, J [1 ]
Sigler, K [1 ]
机构
[1] ACAD SCI CZECH REPUBL, INST MICROBIOL, CR-14220 PRAGUE, CZECH REPUBLIC
关键词
membrane potential; fluorescent probes; slow dyes; carbocyanine; oxonol; rhodamine; RED-BLOOD-CELLS; FLOW CYTOMETRIC ANALYSIS; CONVOLUTED TUBULE CELLS; VOLTAGE-SENSING DYES; PLASMA-MEMBRANE; OXONOL DYES; MITOCHONDRIAL DYSFUNCTION; OPTICAL MEASUREMENT; LIPID VESICLES; CYCLOSPORINE-A;
D O I
10.1016/1011-1344(96)07283-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Basic tenets related to the use of three main classes of potentiometric redistribution fluorescent dyes (carbocyanines, oxonols, and rhodamines) are discussed in detail. They include the structure/function relationship, formation of nonfluorescent (H-type) and fluorescent (J-type) dimers and higher aggregates, probe partitioning between membranes and medium and binding to membranes and intracellular components (with attendant changes in absorption and emission spectra, fluorescence quantum yield and lifetime). The crucial importance of suitable probe-to-cell concentration ratio and selection of optimum monitored fluorescence wavelength is illustrated in schematic diagrams and possible artifacts or puzzling results stemming from faulty experimental protocol are pointed out. Special attention is paid to procedures used for probe-response calibration (potential clamping by potassium in the presence of valinomycin, use of gramicidin D in combination with N-methylglucamine, activation of Ca-dependent K-channels by A23187, the null-point technique). Among other problems treated are dye toxicity, interaction with mitochondria and other organelles, and possible effects of intracellular pH and the quantity of cytosolic proteins and/or RNA on probe response. Individual techniques using redistribution dyes (fluorescence measurements in cuvettes, flow cytometry and microfluorimetry of individual cells including fluorescence confocal microscopy) are discussed in terms of reliability, limitations and drawbacks, and selection of suitable probes. Up-to-date examples of application of slow dyes illustrate the broad range of problems in which these probes can be used.
引用
收藏
页码:101 / 124
页数:24
相关论文
共 206 条
[21]   A TEST OF THE SINGLET OXYGEN MECHANISM OF CATIONIC DYE PHOTOSENSITIZATION OF MITOCHONDRIAL DAMAGE [J].
BUNTING, JR .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1992, 55 (01) :81-87
[22]   INFLUX AND EFFLUX KINETICS OF CATIONIC DYE BINDING TO RESPIRING MITOCHONDRIA [J].
BUNTING, JR .
BIOPHYSICAL CHEMISTRY, 1992, 42 (02) :163-175
[23]   NONLINEAR RELATIONSHIP BETWEEN FLUORESCENCE AND MEMBRANE-POTENTIAL [J].
BURCKHARDT, G .
BIOCHIMICA ET BIOPHYSICA ACTA, 1977, 468 (02) :227-237
[24]   MECHANISM OF INTERACTION OF THE CYANINE DYE DIS-C3-(5) WITH RENAL BRUSH-BORDER VESICLES [J].
CABRINI, G ;
VERKMAN, AS .
JOURNAL OF MEMBRANE BIOLOGY, 1986, 90 (02) :163-175
[25]   MODULATION OF RHODAMINE-123 UPTAKE BY NIGERICIN IN SENSITIVE AND MULTIDRUG-RESISTANT LEUKEMIC-CELLS [J].
CANITROT, Y ;
LAUTIER, D ;
VIALLET, P ;
SALMON, JM .
CANCER LETTERS, 1994, 84 (01) :75-83
[26]  
CANTOR CR, 1980, BIOPHYSICAL CHEM 2, pCH7
[27]  
CAPUOZZO E, 1993, BIOCHEM MOL BIOL INT, V30, P1071
[28]  
CHEN LB, 1989, METHOD CELL BIOL, V29, P103
[29]  
Chen LB, 1993, FLUORESCENT LUMINESC, P124
[30]   FLUORESCENT PROTEIN-DYE CONJUGATES .2. GAMMA GLOBULIN CONJUGATED WITH VARIOUS DYES [J].
CHEN, RF .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1969, 133 (02) :263-&