Morphological character of cervical spine for anterior transpedicular screw fixation

被引:7
作者
Zhou, Rong-Ping [1 ]
Jiang, Jian [1 ]
Zhan, Zi-Chun [1 ]
Zhou, Yang [1 ]
Liu, Zhi-Li [1 ]
Yin, Qing-Shui [2 ]
机构
[1] Nanchang Univ, Dept Orthopaed, Affiliated Hosp 2 & 1, Nanchang 330006, Jiangxi, Peoples R China
[2] Guangzhou Gen Hosp Guangzhou Mil Reg, Guangzhou, Guangdong, Peoples R China
关键词
Cervical anterior pedicle screw; corpectomy; pedicle parameter; MULTILEVEL CORPECTOMY; PEDICLE SCREW; RECONSTRUCTION; INSERTION; FUSION;
D O I
10.4103/0019-5413.121575
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: Anterior cervical interbody grafts/cages combined with a plate were frequently used in multilevel discectomies/corpectomies. In order to avoid additional posterior stabilization in patients who undergo anterior reconstructive surgery, an anterior cervical transpedicular screw fixation, which offers higher stability is desirable. We investigated in this study the anatomical (morphologic) characters for cervical anterior transpedicular screw fixation. Materials and Methods: Left pedicle parameters were measured on computed tomography (CT) images based on 36 cervical spine CT scans from healthy subjects. The parameters included outer pedicle width (Distance from lateral to medial pedicle surface in the coronal plane), outer pedicle height (OPH) (Distance from upper to lower pedicle surface in the sagittal plane), maximal pedicle axis length (MPAL), distance transverse insertion point (DIP), distance of the insertion point to the upper end plate (DIUP), pedicle sagittal transverse angle (PSTA) and pedicle transverse angle (PTA) at C3 to C7. Results: The values of outer pedicle width and MPAL in males were larger than in females from C3 to C7. The OPH in males was larger than in females at C3 to C6, but there was no difference at C7. The DIP and PTA were significantly greater in males than in females at C3, but there was no difference in the angle at C4-7. The PSTA was not statistically different between genders at C3, 4, 7, but this value in males was larger than females at C5, 6. The DIUP was significantly greater in males at C3, 4, 6, 7 but was non significant at C5. Conclusions: The placement of cervical anterior transpedicular screws should be individualized for each patient and based on a detailed preoperative planning.
引用
收藏
页码:553 / 558
页数:6
相关论文
共 20 条
[1]
Long-term biomechanical stability and clinical improvement after extended multilevel corpectomy and circumferential reconstruction of the cervical spine using titanium mesh cages [J].
Acosta, Frank L., Jr. ;
Aryan, Henry E. ;
Chou, Dean ;
Ames, Christopher P. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (03) :165-174
[2]
Surgical results and complications in a series of 71 consecutive cervical spondylotic corpectomies [J].
Bilbao, Gaizka ;
Duart, Melchor ;
Aurrecoechea, Juan Jose ;
Pomposo, Inigo ;
Igartua, Alfonso ;
Catalan, Gregorio ;
Jauregui, Maria Luisa ;
Garibi, Jesus .
ACTA NEUROCHIRURGICA, 2010, 152 (07) :1155-1163
[3]
Perioperative Complications of Combined Anterior and Posterior Cervical Decompression and Fusion Crossing the Cervico-Thoracic Junction [J].
Hart, Robert A. ;
Tatsumi, Robert L. ;
Hiratzka, Jayme R. ;
Yoo, Jung U. .
SPINE, 2008, 33 (26) :2887-2891
[4]
Johnston Todd L, 2006, Spine J, V6, P667
[5]
Reconstruction after multilevel corpectomy in the cervical spine - A sagittal plane biomechanical study [J].
Kirkpatrick, JS ;
Levy, JA ;
Carillo, J ;
Moeini, RS .
SPINE, 1999, 24 (12) :1186-1190
[6]
Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites [J].
Koller, Heiko ;
Hempfing, Axel ;
Acosta, Frank ;
Fox, Michael ;
Scheiter, Armin ;
Tauber, Mark ;
Holz, Ulrich ;
Resch, Herbert ;
Hitzl, Wolfgang .
EUROPEAN SPINE JOURNAL, 2008, 17 (04) :523-538
[7]
The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping [J].
Koller, Heiko ;
Schmidt, Rene ;
Mayer, Michael ;
Hitzl, Wolfgang ;
Zenner, Juliane ;
Middendorf, Stefan ;
Graef, Nicolaus ;
Resch, H. ;
Willke, Hans-Joachim .
EUROPEAN SPINE JOURNAL, 2010, 19 (12) :2137-2148
[8]
Anterior cervical multilevel decompression and fusion using fibular strut as revision surgery for failed cervical laminoplasty [J].
Komura, Shingo ;
Miyamoto, Kei ;
Hosoe, Hideo ;
Fushimi, Kazunari ;
Iwai, Chizuo ;
Nishimoto, Hirofumi ;
Shimizu, Katsuji .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) :1177-1185
[9]
Comparison of ventral corpectomy and plate-screw-instrumented fusion with dorsal laminectomy and rod-screw-instrumented fusion for treatment of at least two vertebral-level spondylotic cervical myelopathy [J].
Kristof, Rudolf Andreas ;
Kiefer, Thomas ;
Thudium, Marcus ;
Ringel, Florian ;
Stoffel, Michael ;
Kovacs, Attlila ;
Mueller, Christian-Andreas .
EUROPEAN SPINE JOURNAL, 2009, 18 (12) :1951-1956
[10]
[Li Pingyue 李凭跃], 2008, [中国组织工程研究与临床康复, Journal of Clinical Rehabilitative Tissue Engineering Research], V12, P3381