A tailored approach to catheter ablation of paroxysmal atrial fibrillation

被引:163
作者
Oral, H [1 ]
Chugh, A [1 ]
Good, E [1 ]
Sankaran, S [1 ]
Reich, SS [1 ]
Igic, P [1 ]
Elmouchi, D [1 ]
Tschopp, D [1 ]
Crawford, T [1 ]
Dey, S [1 ]
Wimmer, A [1 ]
Lemola, K [1 ]
Jongnarangsin, K [1 ]
Bogun, F [1 ]
Pelosi, F [1 ]
Morady, F [1 ]
机构
[1] Univ Michigan, Div Cardiovasc Med, Ann Arbor, MI 48109 USA
关键词
ablation; arrhythmia; atrium; catheter ablation; fibrillation;
D O I
10.1161/CIRCULATIONAHA.105.601898
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Because the genesis of atrial fibrillation (AF) is multifactorial and variable, an ablation strategy that involves pulmonary vein isolation and/or a particular set of ablation lines may not be equally effective or efficient in all patients with AF. A tailored strategy that targets initiators and drivers of AF is a possible alternative to a standardized lesion set. Methods and Results - Catheter ablation was performed in 153 consecutive patients ( mean age, 56 +/- 11 years) with symptomatic paroxysmal AF with the use of an 8-mm tip radiofrequency ablation catheter. The esophagus was visualized with barium. The pulmonary veins and left atrium were mapped during spontaneous or induced AF. Arrhythmogenic pulmonary veins were isolated or encircled. If AF was still present or inducible, complex electrograms in the left atrium, coronary sinus, and superior vena cava were targeted for ablation. The end point of ablation was absence of frequent atrial ectopy and spontaneous AF during isoproterenol infusion and noninducibility of AF. Routine energy applications near the esophagus were avoided. During follow-up, left atrial flutter developed in 19% of patients and was still present in 10% at > 12 weeks of follow-up. A repeat ablation procedure was performed in 18% of patients. During a mean follow-up of 11 +/- 4 months, 77% of patients were free from AF and/or atrial flutter without antiarrhythmic drug therapy. Pericardial tamponade or transient neurological events occurred in 2% of procedures. Conclusions - A tailored ablation strategy that only targets triggers and drivers of AF is feasible and eliminates paroxysmal AF in approximate to 80% of patients.
引用
收藏
页码:1824 / 1831
页数:8
相关论文
共 33 条
[31]   Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation [J].
Scanavacca, MI ;
Avila, AD ;
Parga, J ;
Sosa, E .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (08) :960-962
[32]   Autonomically induced conversion of pulmonary vein focal firing into atrial fibrillation [J].
Scherlag, BJ ;
Yamanashi, W ;
Patel, U ;
Lazzara, R ;
Jackman, WM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (11) :1878-1886
[33]   Spatiotemporal periodicity during atrial fibrillation in the isolated sheep heart [J].
Skanes, AC ;
Mandapati, R ;
Berenfeld, O ;
Davidenko, JM ;
Jalife, J .
CIRCULATION, 1998, 98 (12) :1236-1248