Combination of suppressed and non-suppressed ion chromatography with atmospheric pressure ionization mass spectrometry for the determination of anions

被引:45
作者
Buchberger, W [1 ]
Ahrer, W [1 ]
机构
[1] Univ Linz, Dept Analyt Chem, A-4040 Linz, Austria
关键词
water analysis; inorganic anions; oxyhalides;
D O I
10.1016/S0021-9673(99)00273-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Non-suppressed and suppressed ion chromatography in combination with atmospheric pressure ionization mass spectrometry are compared with special respect to sensitivity for the analysis of low-molecular-mass anions. Iodate, bromate, bromide, sulfate, thiosulfate and bromide could be separated by non-suppressed ion chromatography using a low-capacity anion-exchange column and ammonium citrate as mobile phase. Absolute detection limits between 0.4 and 0.7 ng could be achieved; employing a column requiring a flow-rate of 1 ml/min for optimum performance, splitting was necessary so that only 120 mu l/min entered the interface of the mass spectrometer resulting in detection Limits between 0.03 and 0.06 mg/l. The same stationary phase (packed into a narrow-bore column which allowed operation without: splitting) was suitable for the separation of oxyhalides in the suppressed mode with detection limits of 0.5 mu g/l (50 pg) with sodium carbonate as eluent. The method was applied to the analysis of drinking water for oxyhalides. The sample pretreatment for the removal of matrix anions (sulfate, chloride and hydrogencarbonate) is described. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 28 条
[1]   Studies on the combination of ion chromatography particle-beam mass spectrometry with capillary columns [J].
Buchberger, W ;
Haider, K .
JOURNAL OF CHROMATOGRAPHY A, 1997, 770 (1-2) :59-68
[2]   CHROMIUM SPECIATION BY ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH BOTH INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPIC AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
BYRDY, FA ;
OLSON, LK ;
VELA, NP ;
CARUSO, JA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (02) :311-320
[3]   Electrospray ion chromatography tandem mass spectrometry of oxyhalides at sub-ppb levels [J].
Charles, L ;
Pépin, D .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :353-359
[4]   Electrospray ion chromatography tandem mass spectrometry of bromate at sub-ppb levels in water [J].
Charles, L ;
Pepin, D ;
Casetta, B .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2554-2558
[5]   Determination of bromate in drinking waters by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Pfaff, JD ;
Brockhoff, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :261-267
[6]   Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography [J].
Diemer, J ;
Heumann, KG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :74-79
[7]   ORGANIC-ACID ELUENTS FOR SINGLE-COLUMN ION CHROMATOGRAPHY [J].
FRITZ, JS ;
DUVAL, DL ;
BARRON, RE .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :1177-1182
[8]   SODIUM AND POTASSIUM BENZOATE AND BENZOIC-ACID AS ELUENTS FOR ION CHROMATOGRAPHY [J].
GJERDE, DT ;
FRITZ, JS .
ANALYTICAL CHEMISTRY, 1981, 53 (14) :2324-2327
[9]   ANION CHROMATOGRAPHY WITH LOW-CONDUCTIVITY ELUENTS .2. [J].
GJERDE, DT ;
SCHMUCKLER, G ;
FRITZ, JS .
JOURNAL OF CHROMATOGRAPHY, 1980, 187 (01) :35-45
[10]   DETERMINATION OF ARSENIC COMPOUNDS USING INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITH ION CHROMATOGRAPHY [J].
INOUE, Y ;
KAWABATA, K ;
TAKAHASHI, H ;
ENDO, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 675 (1-2) :149-154