Chronic measurement of cardiac output in conscious mice

被引:81
作者
Janssen, B [1 ]
Debets, J [1 ]
Leenders, P [1 ]
Smits, J [1 ]
机构
[1] Univ Maastricht, Dept Pharmacol & Toxicol, Cardiovasc Res Inst Maastricht, NL-6200 MD Maastricht, Netherlands
关键词
heart function; echocardiography; myocardial infarction; spectral analysis;
D O I
10.1152/ajpregu.00406.2001
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We describe the feasibility of chronic measurement of cardiac output (CO) in conscious mice. With the use of gas anesthesia, mice >30 g body wt were instrumented either with transit-time flow probes or electromagnetic probes placed on the ascending aorta. Ascending aortic flow values were recorded 6-16 days after surgery when probes had fully grown in. In the first set of experiments, while mice were under ketamine-xylazine anesthesia, estimates of stroke volume (SV) obtained by the transit-time technique were compared with those simultaneously obtained by echocardiography. Transit-time values of SV were similar to those obtained by echocardiography. The average difference +/- SD between the methods was 2 +/- 7 mul. In the second set of studies, transit-time values of CO were compared with those obtained by the electromagnetic flow probes. In conscious resting conditions, estimates (+/-SD) of cardiac index (CI) obtained by the transit-time and electromagnetic flow probes were 484 +/- 119 and 531 +/- 103 ml.min(-1).kg body wt(-1), respectively. Transit-time flow probes were also implanted in mice with a myocardial infarction (MI) induced by ligation of a coronary artery 3 wk before probe implantation. In these MI mice (n = 7), average (+/-SD) resting and stimulated (by volume loading) values of CO were significantly lower than in noninfarcted mice (n = 15) (resting CO 16 +/- 3 vs. 20 +/- 4 ml/min; stimulated CO 20 +/- 5 vs. 26 +/- 6 ml/min). Finally, using transfer function analysis, we found that, in resting conditions for both intact and MI mice, spontaneous variations in CO (>0.1 Hz) were mainly due to those occurring in SV rather than in heart rate. These data indicate that CO can be measured chronically and reliably in conscious mice, also in conditions of heart failure, and that variations in preload are an important determinant of CO in this species.
引用
收藏
页码:R928 / R935
页数:8
相关论文
共 27 条
  • [1] [Anonymous], 1978, P SAN DIEG BIOM S
  • [2] HEMODYNAMICS IN TRANSGENIC MICE WITH OVEREXPRESSION OF ATRIAL-NATRIURETIC-FACTOR
    BARBEE, RW
    PERRY, BD
    RE, RN
    MURGO, JP
    FIELD, LJ
    [J]. CIRCULATION RESEARCH, 1994, 74 (04) : 747 - 751
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] BROULIK PD, 1973, P SOC EXP BIOL MED, V144, P671
  • [5] Long-term telemetric measurement of cardiovascular parameters in awake mice: a physiological genomics tool
    Butz, GM
    Davisson, RL
    [J]. PHYSIOLOGICAL GENOMICS, 2001, 5 (02) : 89 - 97
  • [6] RESPONSE TO PULSATILE FLOW OF A MINIATURIZED ELECTROMAGNETIC BLOOD-FLOW SENSOR STUDIED BY MEANS OF A LASER-DOPPLER METHOD
    CORVER, JAWM
    KUIKEN, GDC
    VANDERMARK, F
    JANSEN, TC
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (04) : 430 - 437
  • [7] Disruption of the plasminogen gene in mice abolishes wound healing after myocardial infarction
    Creemers, E
    Cleutjens, J
    Smits, J
    Heymans, S
    Moons, L
    Collen, D
    Daemen, M
    Carmeliet, P
    [J]. AMERICAN JOURNAL OF PATHOLOGY, 2000, 156 (06) : 1865 - 1873
  • [8] Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals
    Feldman, MD
    Erikson, JM
    Mao, Y
    Korcarz, CE
    Lang, RM
    Freeman, GL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (04): : H1698 - H1707
  • [9] Development of a multifrequency conductance catheter-based system to determine LV function in mice
    Feldman, MD
    Mao, Y
    Valvano, JW
    Pearce, JA
    Freeman, GL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (03): : H1411 - H1420
  • [10] Inhibition of plasminogen activators or matrix metalloproteinases prevents cardiac rupture but impairs therapeutic angiogenesis and causes cardiac failure
    Heymans, S
    Luttun, A
    Nuyens, D
    Theilmeier, G
    Creemers, E
    Moons, L
    Dyspersin, GD
    Cleutjens, JPM
    Shipley, M
    Angellilo, A
    Levi, M
    Nübe, O
    Baker, A
    Keshet, E
    Lupu, F
    Herbert, JM
    Smits, JFM
    Shapiro, SD
    Baes, M
    Borgers, M
    Collen, D
    Daemen, MJAP
    Carmeliet, P
    [J]. NATURE MEDICINE, 1999, 5 (10) : 1135 - 1142