Rapid and Sensitive Detection of Novel Avian-Origin Influenza A (H7N9) Virus by Reverse Transcription Loop-Mediated Isothermal Amplification Combined with a Lateral-Flow Device

被引:71
作者
Ge, Yiyue [1 ]
Wu, Bin [2 ]
Qi, Xian [2 ]
Zhao, Kangchen [1 ]
Guo, Xiling [1 ]
Zhu, Yefei [2 ]
Qi, Yuhua [1 ]
Shi, Zhiyang [1 ]
Zhou, Minghao [1 ]
Wang, Hua [1 ]
Cui, Lunbiao [1 ]
机构
[1] Minist Hlth, Key Labs Enter Pathogen Microbiol, Jiangsu Prov Ctr Dis Control & Prevent, Inst Pathogen Microbiol, Nanjing, Jiangsu, Peoples R China
[2] Jiangsu Prov Ctr Dis Prevent & Control, Dept Acute Infect Dis Control & Prevent, Nanjing, Jiangsu, Peoples R China
来源
PLOS ONE | 2013年 / 8卷 / 08期
关键词
CROSS-PRIMING AMPLIFICATION; MYCOBACTERIUM-TUBERCULOSIS; FEVER VIRUS; SYSTEM;
D O I
10.1371/journal.pone.0069941
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A severe disease in humans caused by a novel avian-origin influenza A (H7N9) virus emerged in China recently, which has caused at least 128 cases and 26 deaths. Rapid detection of the novel H7N9 virus is urgently needed to differentiate the disease from other infections, and to facilitate infection control as well as epidemiologic investigations. In this study, a reverse transcription loop-mediated isothermal amplification combined with a lateral flow device (RT-LAMP-LFD) assay to rapidly detect H7N9 virus was developed and evaluated. The RT-LAMP primers were designed to target the haemagglutinin (HA) and neuraminidase (NA) genes of H7N9 virus. Results of 10-fold dilution series assays showed that analysis of RT-LAMP products by the LFD method was as sensitive as real-time turbidity detection, and that the analytic sensitivities of the HA and NA RT-LAMP assays were both 10 copies of synthetic RNA. Furthermore, both the assays showed 100% clinical specificity for identification of H7N9 virus. The performance characteristics of the RT-LAMP-LFD assay were evaluated with 80 clinical specimens collected from suspected H7N9 patients. The NA RT-LAMP-LFD assay was more sensitive than real time RT-PCR assay. Compared with a combination of virus culture and real-time RT-PCR, the sensitivity, specificity, positive predictive value, and negative predictive value of the RT-LAMP-LFD assay were all 100%. Overall, The RT-LAMP-LFD assay established in this study can be used as a reliable method for early diagnosis of the avian-origin influenza A (H7N9) virus infection.
引用
收藏
页数:7
相关论文
共 31 条
  • [1] Application of isothermal helicase-dependent amplification with a disposable detection device in a simple sensitive stool test for toxigenic Clostridium difficile
    Chow, Wing Huen A.
    McCloskey, Cindy
    Tong, Yanhong
    Hu, Lin
    You, Qimin
    Kelly, Ciaran P.
    Kong, Huimin
    Tang, Yi-Wei
    Tang, Wen
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (05) : 452 - 458
  • [2] Corman VM, 2013, EUROSURVEILLANCE, V18, P10
  • [3] Detection of Severe Fever with Thrombocytopenia Syndrome Virus by Reverse Transcription-Cross-Priming Amplification Coupled with Vertical Flow Visualization
    Cui, Lunbiao
    Ge, Yiyue
    Qi, Xian
    Xu, Gaolian
    Li, Haijing
    Zhao, Kangchen
    Wu, Bin
    Shi, Zhiyang
    Guo, Xiling
    Hu, Lin
    You, Qimin
    Zhang, Li-Hong
    Freiberg, Alexander N.
    Yu, Xuejie
    Wang, Hua
    Zhou, Minghao
    Tang, Yi-Wei
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (12) : 3881 - 3885
  • [4] Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP)
    Curtis, Kelly A.
    Rudolph, Donna L.
    Owen, S. Michele
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2008, 151 (02) : 264 - 270
  • [5] Novel reverse transcription loop-mediated isothermal amplification for rapid detection of foot-and-mouth disease virus
    Dukes, J. P.
    King, D. P.
    Alexandersen, S.
    [J]. ARCHIVES OF VIROLOGY, 2006, 151 (06) : 1093 - 1106
  • [6] Cross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens
    Fang, Rendong
    Li, Xia
    Hu, Lin
    You, Qimin
    Li, Jing
    Wu, Jie
    Xu, Peng
    Zhong, Huayan
    Luo, Ying
    Mei, Jian
    Gao, Qian
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (03) : 845 - 847
  • [7] Hendra virus detection using Loop-Mediated Isothermal Amplification
    Foord, Adam J.
    Middleton, Deborah
    Heine, Hans G.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2012, 181 (01) : 93 - 96
  • [8] Human Infection with a Novel Avian-Origin Influenza A (H7N9) Virus
    Gao, Rongbao
    Cao, Bin
    Hu, Yunwen
    Feng, Zijian
    Wang, Dayan
    Hu, Wanfu
    Chen, Jian
    Jie, Zhijun
    Qiu, Haibo
    Xu, Ke
    Xu, Xuewei
    Lu, Hongzhou
    Zhu, Wenfei
    Gao, Zhancheng
    Xiang, Nijuan
    Shen, Yinzhong
    He, Zebao
    Gu, Yong
    Zhang, Zhiyong
    Yang, Yi
    Zhao, Xiang
    Zhou, Lei
    Li, Xiaodan
    Zou, Shumei
    Zhang, Ye
    Li, Xiyan
    Yang, Lei
    Guo, Junfeng
    Dong, Jie
    Li, Qun
    Dong, Libo
    Zhu, Yun
    Bai, Tian
    Wang, Shiwen
    Hao, Pei
    Yang, Weizhong
    Zhang, Yanping
    Han, Jun
    Yu, Hongjie
    Li, Dexin
    Gao, George F.
    Wu, Guizhen
    Wang, Yu
    Yuan, Zhenghong
    Shu, Yuelong
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (20) : 1888 - 1897
  • [9] Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection
    Imai, Masaki
    Ninomiya, Ai
    Minekawa, Harumi
    Notomi, Tsugunori
    Ishizaki, Toru
    Tashiro, Masato
    Odagiri, Takato
    [J]. VACCINE, 2006, 24 (44-46) : 6679 - 6682
  • [10] Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples
    Iwamoto, T
    Sonobe, T
    Hayashi, K
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) : 2616 - 2622