Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses

被引:263
作者
Hart, JP
Wring, SA
机构
[1] GLAXO INC,BIOANAL & DRUG METAB DIV,RES TRIANGLE PK,NC 27709
[2] UNIV W ENGLAND,FAC SCI APPL,BRISTOL BS16 1QY,AVON,ENGLAND
关键词
D O I
10.1016/S0165-9936(96)00097-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This review presents recent developments in the design and application of disposable, screen-printed electrochemical sensors for biomedical, environmental and industrial analyses, Particular emphasis is given to the fabrication techniques and electrode processes employed; applications are included where available.
引用
收藏
页码:89 / 103
页数:15
相关论文
共 72 条
  • [1] AMPEROMETRIC ASSAY FOR THE KETONE-BODY 3-HYDROXYBUTYRATE
    BATCHELOR, MJ
    GREEN, MJ
    SKETCH, CL
    [J]. ANALYTICA CHIMICA ACTA, 1989, 221 (02) : 289 - 294
  • [2] DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING
    CAGNINI, A
    PALCHETTI, I
    LIONTI, I
    MASCINI, M
    TURNER, APF
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 85 - 89
  • [3] Ruthenized screen-printed choline oxidase-based biosensors for measurement of anticholinesterase activity
    Cagnini, A
    Palchetti, I
    Mascini, M
    Turner, APF
    [J]. MIKROCHIMICA ACTA, 1995, 121 (1-4) : 155 - 166
  • [4] SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE
    CARDOSI, MF
    BIRCH, SW
    [J]. ANALYTICA CHIMICA ACTA, 1993, 276 (01) : 69 - 74
  • [5] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [6] CRASTON DH, 1991, TALANTA, V38, P39
  • [7] DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME
    DEGANI, Y
    HELLER, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) : 1285 - 1289
  • [8] ADAPTATION OF ONLINE REACTIONS DEVELOPED FOR USE WITH FLOW-INJECTION WITH AMPEROMETRIC DETECTION FOR USE IN DISPOSABLE SENSOR DEVICES - REDUCTIVE DETERMINATION OF PHOSPHATE AS PREFORMED 12-MOLYBDOPHOSPHATE IN A CAPILLARY-FILL DEVICE
    FOGG, AG
    SCULLION, SP
    EDMONDS, TE
    BIRCH, BJ
    [J]. ANALYST, 1990, 115 (10) : 1277 - 1281
  • [9] DIRECT REDUCTIVE AMPEROMETRIC DETERMINATION OF NITRATE AT A COPPER ELECTRODE FORMED INSITU IN A CAPILLARY-FILL SENSOR DEVICE
    FOGG, AG
    SCULLION, SP
    EDMONDS, TE
    BIRCH, BJ
    [J]. ANALYST, 1991, 116 (06) : 573 - 579
  • [10] IMPROVING THE PERFORMANCE OF SCREEN-PRINTED CARBON AND POLISHED PLATINUM AND GLASSY-CARBON VOLTAMMETRIC ELECTRODES BY MODIFICATION WITH POLY-L-LYSINE
    FOGG, AG
    PIRZAD, R
    MOREIRA, JC
    DAVIES, AE
    [J]. ANALYTICAL PROCEEDINGS, 1995, 32 (06): : 209 - 212