Potentiometric pH sensors based on electrodeposited polymers

被引:64
作者
Lakard, B [1 ]
Herlem, G [1 ]
Lakard, S [1 ]
Guyetant, R [1 ]
Fahys, B [1 ]
机构
[1] Univ Franche Comte, LCMI, F-25030 Besancon, France
关键词
electrochemical polymerization; surface modification; potentiometric pH sensors;
D O I
10.1016/j.polymer.2005.10.095
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Five potentiometric pH sensors based on thin polymer films, obtained from electropolymerization of their respective monomers: 1,3-diaminopropane, diethylenetriamine, pyrrole, p-phenylenediamine and aniline, were compared. All these molecules have been chosen since they contain amino groups, which are sensitive to proton concentration changes. The resulting sensors consist in a polymer-coated smooth platinum wire protruded from glass sheath. Their potentiometric responses appeared linear in the range from pH 2 to 11. These electrodes present also a good reversibility and a good stability in time over a period of 1 month. The response mechanisms are also examined. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:12233 / 12239
页数:7
相关论文
共 10 条
[1]   ANIONIC RESPONSES OF ELECTROCHEMICALLY SYNTHESIZED POLYPYRROLE FILMS [J].
CADOGAN, A ;
LEWENSTAM, A ;
IVASKA, A .
TALANTA, 1992, 39 (06) :617-620
[2]   pH sensor based on deposited film of lead oxide on aluminum substrate electrode [J].
Eftekhari, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (03) :234-238
[3]   POLYMER FILM CHEMICALLY MODIFIED ELECTRODE AS A POTENTIOMETRIC SENSOR [J].
HEINEMAN, WR ;
WIECK, HJ ;
YACYNYCH, AM .
ANALYTICAL CHEMISTRY, 1980, 52 (02) :345-346
[4]   A method of reducing oxygen induced drift in iridium oxide pH sensors [J].
Hendrikse, J ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :97-103
[5]   pH sensing at Pt electrode surfaces coated with linear polyethylenimine from anodic polymerization of ethylenediamine [J].
Herlem, G ;
Lakard, B ;
Herlem, M ;
Fahys, B .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2001, 148 (11) :E435-E438
[6]   THE BEHAVIOR OF POLYPYRROLE DOPED WITH DIFFERENT ANIONS AS AN ION-SELECTIVE ELECTRODE [J].
JOVANOVIC, VM ;
MARKICEVIC, L ;
STANKOVIC, S ;
STANKOVIC, R ;
JOVANOVIC, MS .
ELECTROANALYSIS, 1995, 7 (06) :574-578
[7]   Miniaturized pH biosensors based on electrochemically modified electrodes with biocompatible polymers [J].
Lakard, B ;
Herlem, G ;
de Labachelerie, M ;
Daniau, W ;
Martin, G ;
Jeannot, JC ;
Robert, L ;
Fahys, B .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :595-606
[8]   ON THE NATURE OF THE POTENTIOMETRIC RESPONSE OF POLYPYRROLE IN ACIDIC SOLUTIONS [J].
MICHALSKA, A ;
MAKSYMIUK, K ;
HULANICKI, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 392 (1-2) :63-68
[9]  
QINGWEN L, 2000, ANAL CHIM ACTA, V409, P137
[10]   Molybdenum oxide bronzes as pH sensors [J].
Shuk, P ;
Ramanujachary, KV ;
Greenblatt, M .
ELECTROCHIMICA ACTA, 1996, 41 (13) :2055-2058