Miniaturized pH biosensors based on electrochemically modified electrodes with biocompatible polymers

被引:48
作者
Lakard, B
Herlem, G
de Labachelerie, M
Daniau, W
Martin, G
Jeannot, JC
Robert, L
Fahys, B
机构
[1] Univ Franche Comte, UFR Sci, LCMI, F-25030 Besancon, France
[2] CNRS, LPMO, UPR 3203, F-25044 Besancon, France
关键词
electrochemical polymerization; surface modification; thin films; potentiometric pH biosensors; microsystem technology;
D O I
10.1016/S0956-5663(03)00270-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Potentiometric pH sensors based on linear polyethylenimine (L-PEI) and linear polypropylenimine(L-PPI), two synthetic enzymes and biocompatible polymers, films were prepared by electropolymerization of three different monomers: ethylenediamine (EDA), 1,3-diaminopropane (1,3-DAP) and diethylenetriamine (DETA) in order to be used in clinical, dermatological and biological applications, such as in vivo analysis. In a first step a biosensor was tested which consisted in a platinum wire protruded from glass sheath. The polymer film coated on these platinum electrodes showed good linear potentiometric responses to pH changes from pH 3 to 10. Resulting electrodes present both good reversibility and good stability versus time. The effect of the different polymer film thicknesses to potentiometric responses was also studied. This study allowed us to develop a miniaturized pH biosensor in the second step. This sensor was fabricated using photolithography, followed by sputtering and lift-off processes, and it included an electronic detection system. We have also successfully studied the potentiometric responses to pH changes of this device over a period of I month, and so we propose this new pH microbiosensor as an alternative to classical pH sensors currently used in dermatology. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:595 / 606
页数:12
相关论文
共 19 条
[1]   ANIONIC RESPONSES OF ELECTROCHEMICALLY SYNTHESIZED POLYPYRROLE FILMS [J].
CADOGAN, A ;
LEWENSTAM, A ;
IVASKA, A .
TALANTA, 1992, 39 (06) :617-620
[2]   ELECTRONIC SEMICONDUCTING OXIDES AS PH SENSORS [J].
FOG, A ;
BUCK, RP .
SENSORS AND ACTUATORS, 1984, 5 (02) :137-146
[3]   Surface modification of platinum and gold electrodes by anodic oxidation of pure ethylenediamine [J].
Herlem, G ;
Goux, C ;
Fahys, B ;
Dominati, F ;
Goncalves, AM ;
Mathieu, C ;
Sutter, E ;
Trokourey, A ;
Penneau, JF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 435 (1-2) :259-265
[4]   pH sensing at Pt electrode surfaces coated with linear polyethylenimine from anodic polymerization of ethylenediamine [J].
Herlem, G ;
Lakard, B ;
Herlem, M ;
Fahys, B .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2001, 148 (11) :E435-E438
[5]   Surface modification of p-Si by a polyethylenimine coating: influence of the surface pre-treatment. Application to a potentiometric transducer as pH sensor [J].
Herlem, M ;
Fahys, B ;
Herlem, G ;
Lakard, B ;
Reybier, K ;
Trokourey, A ;
Diaco, T ;
Zairi, S ;
Jaffrezic-Renault, N .
ELECTROCHIMICA ACTA, 2002, 47 (16) :2597-2602
[6]   Potentiometric pH sensors based on chemically modified electrodes with electropolymerized metal-tetraaminophthalocyanine [J].
Kang, TF ;
Xie, ZY ;
Tang, H ;
Shen, GL ;
Yu, RQ .
TALANTA, 1997, 45 (02) :291-296
[7]   The improved potentiometric pH response of electrodes modified with processible polyaniline. Application to glucose biosensor [J].
Karyakin, AA ;
Lukachova, LV ;
Karyakina, EE ;
Orlov, AV ;
Karpachova, GP .
ANALYTICAL COMMUNICATIONS, 1999, 36 (04) :153-156
[8]   Spectroscopic and ab initio study of polymeric films used as chemical sensors [J].
Lakard, B ;
Herlem, G ;
Herlem, M ;
Etcheberry, A ;
Morvan, J ;
Fahys, B .
SURFACE SCIENCE, 2002, 502 :296-303
[9]   Ab initio study of the electrochemical polymerization mechanism leading from DETA to PEI [J].
Lakard, B ;
Herlem, G ;
Fahys, B .
JOURNAL OF MOLECULAR STRUCTURE-THEOCHEM, 2002, 593 :133-141
[10]   Ab initio study of the electrochemical polymerization mechanism of ω-diamines [J].
Lakard, B ;
Herlem, G ;
Fahys, B .
JOURNAL OF CHEMICAL PHYSICS, 2001, 115 (15) :7219-7226