Significance of background optical properties, time-resolved information and optode arrangement in diffuse optical imaging of term neonates

被引:30
作者
Heiskala, J. [1 ,2 ]
Hiltunen, P. [2 ]
Nissila, I. [2 ,3 ]
机构
[1] Univ Helsinki, Cent Hosp, BioMag Lab, HUSLAB, FI-00029 Helsinki, Finland
[2] Aalto Univ, Dept Biomed Engn & Computat Sci, FI-02015 Espoo, Finland
[3] Univ Helsinki, Inst Biomed, FI-00014 Hy, Finland
基金
芬兰科学院;
关键词
NEAR-INFRARED SPECTROSCOPY; NON-SCATTERING REGIONS; HUMAN BRAIN-FUNCTION; PHOTON MIGRATION; FREQUENCY-DOMAIN; INFANT BRAIN; ADULT HEAD; NONSCATTERING REGIONS; RADIATIVE-TRANSFER; LIGHT-PROPAGATION;
D O I
10.1088/0031-9155/54/3/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The significance of accurate knowledge of background optical properties and time-resolved information in reconstructing images of hemodynamic changes in the neonatal brain from diffuse optical imaging data was studied using Monte Carlo (MC) simulation. A segmented anatomical magnetic resonance (MR) image and literature-derived optical properties for each tissue type were used to create a voxel-based anatomical model. Small absorbing perturbations were introduced into the anatomical model to simulate localized hemodynamic responses related to brain activation. Perturbation MC (pMC) was used as the primary method of image reconstruction. For comparison, reconstructions were also performed using the finite element method (FEM) to solve the diffusion approximation (DA) to the radiative transfer equation (RTE). The effect of optode layout was investigated using three different grids. Of the factors studied, the density of the optode grid was found to have the greatest effect on image quality. The use of time-resolved information significantly improved the spatial accuracy with all optode grids. Adequate knowledge and modeling of the optical properties of the background was found to significantly improve the spatial accuracy of the reconstructed images and make the recovery of contrast of absorption changes more consistent over simplified modeling. Localization accuracy of small perturbations was found to be 2-3 mm with accurate a priori knowledge of the background optical properties, when a grid with high optode density (> 1 optode cm(-2)) was used.
引用
收藏
页码:535 / 554
页数:20
相关论文
共 57 条
[51]   Coupled radiative transfer equation and diffusion approximation model for photon migration in turbid medium with low-scattering and non-scattering regions [J].
Tarvainen, T ;
Vauhkonen, M ;
Kolehmainen, V ;
Arridge, SR ;
Kaipio, JP .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4913-4930
[52]   Study of local cerebral hemodynamics by frequency-domain near-infrared spectroscopy and correlation with simultaneously acquired functional magnetic resonance imaging [J].
Toronov, V ;
Webb, A ;
Choi, JH ;
Wolf, M ;
Safonova, L ;
Wolf, U ;
Gratton, E .
OPTICS EXPRESS, 2001, 9 (08) :417-427
[53]   Photon path distribution and optical responses of turbid media: theoretical analysis based on the microscopic Beer-Lambert law [J].
Tsuchiya, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08) :2067-2084
[54]   Non-invasive optical spectroscopy and imaging of human brain function [J].
Villringer, A ;
Chance, B .
TRENDS IN NEUROSCIENCES, 1997, 20 (10) :435-442
[55]   MCML - MONTE-CARLO MODELING OF LIGHT TRANSPORT IN MULTILAYERED TISSUES [J].
WANG, LH ;
JACQUES, SL ;
ZHENG, LQ .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1995, 47 (02) :131-146
[56]   Using near-infrared spectroscopy to assess neural activation during object processing in infants [J].
Wilcox, T ;
Bortfeld, H ;
Woods, R ;
Wruck, E ;
Boas, DA .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (01)
[57]   Retinotopic mapping of adult human visual cortex with high-density diffuse optical tomography [J].
Zeff, Benjamin W. ;
White, Brian R. ;
Dehghani, Hamid ;
Schlaggar, Bradley L. ;
Culver, Joseph P. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (29) :12169-12174