Chest radiography: Depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography

被引:38
作者
Woodard, PK
Slone, RM
Gierada, DS
Reiker, GG
Pilgram, TK
Jost, RG
机构
[1] Electronic Radiology Laboratory, Mallinckrodt Institute of Radiology, Washington Univ. School of Medicine, St Louis, MO 63110
关键词
lung; radiosaphy; radiography; comparative studies; digital; thorax;
D O I
10.1148/radiology.203.1.9122392
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the subjective visibility of normal anatomy and pathologic structures in the chest on conventional screen-film radiographs versus selenium-based digital radiographs. MATERIALS AND METHODS: Screen-film and digital standard posteroanterior (PA) and lateral chest radiographs were obtained in 49 patients (32 men, 17 women; mean age, 60 years; range, 24-91 years) undergoing chest computed tomography (CT). Conventional images were phototimed at 115 kVp with use of a wide-latitude screen-film system and an antiscatter grid. Digital images were obtained at 150 kVp with use of a commercial system with a selenium detector and an air gap alone for scatter reduction. The image sets were independently compared by four radiologists, and the relative visibility of anatomic and pathologic features (proved at CT) was graded. Statistical significance (P < .0028) was evaluated with a one-tailed t test. RESULTS: Visibility with the digital images was statistically significantly increased for 11 of 13 normal anatomic features and for pathologic structures in the lung, soft tissue, and bone. CONCLUSION: Subjective visibility of pathologic structures and most normal anatomic features in the thorax was statistically significantly improved with selenium-based digital chest radiography compared with conventional screen-film chest radiography.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 12 条
[1]  
Balter S., 1993, Medicamundi, V38, P94
[2]   TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR [J].
CHOTAS, HG ;
FLOYD, CE ;
RAVIN, CE .
RADIOLOGY, 1995, 195 (01) :264-270
[3]   Economic aspects and cost calculations for a digital selenium-based chest imaging system [J].
deValois, JC ;
vanHeesewijk, HPM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) :950-952
[4]  
FLOYD CE, 1994, P SOC PHOTO-OPT INS, V2163, P110
[5]   DIGITAL CHEST IMAGING WITH A SELENIUM DETECTOR - COMPARISON WITH CONVENTIONAL RADIOGRAPHY FOR VISUALIZATION OF SPECIFIC ANATOMIC REGIONS OF THE CHEST [J].
HEESEWIJK, HPM ;
NEITZEL, U ;
VANDERGRAAF, Y ;
DEVALOIS, JC ;
FELDBERG, MAM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :535-540
[6]  
MAACK I, 1991, COMPUTER ASSISTED RA, P1090
[7]   GRIDS OR AIR GAPS FOR SCATTER REDUCTION IN DIGITAL RADIOGRAPHY - A MODEL CALCULATION [J].
NEITZEL, U .
MEDICAL PHYSICS, 1992, 19 (02) :475-481
[8]   IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR [J].
NEITZEL, U ;
MAACK, I ;
GUNTHERKOHFAHL, S .
MEDICAL PHYSICS, 1994, 21 (04) :509-516
[9]  
SLONE RM, 1996, RADIOLOGY, V201, P400
[10]   Chest imaging with a selenium detector versus conventional film radiography: A CT-controlled study [J].
vanHeesewijk, HPM ;
vanderGraaf, Y ;
deValois, JC ;
Vos, AJ ;
Feldberg, MAM .
RADIOLOGY, 1996, 200 (03) :687-690