Strategies for isotope ratio measurements with a double focusing sector field ICP-MS

被引:24
作者
Hamester, M [1 ]
Wiederin, D [1 ]
Wills, J [1 ]
Kerl, W [1 ]
Douthitt, CB [1 ]
机构
[1] Finnigan MAT GmbH, D-28197 Bremen, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1999年 / 364卷 / 05期
关键词
D O I
10.1007/s002160051374
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single collector double focusing sector field ICP-MS is evaluated for the determination of isotope ratios. Spectral interferences (e.g. (ArNa)-Ar-40-Na-23 on Cu-63) can lead to calculation of inaccurate ratios. The use of high resolution enables such interferences to be separated from the isotopes of interest. External reproducibilities of < 0.02% are shown for uninterfered isotopes (measured at low resolution R = 300) and < 0.1% for interfered isotopes which required the use of medium (R = 4000) and high resolution (R = 10000).
引用
收藏
页码:495 / 497
页数:3
相关论文
共 15 条
[1]   Double-focusing sector field inductively coupled plasma mass spectrometry for highly sensitive multi-element and isotopic analysis - Invited lecture [J].
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :881-889
[2]   NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - SOME PRELIMINARY MEASUREMENTS [J].
INCE, AT ;
WILLIAMS, JG ;
GRAY, AL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :899-&
[3]   Isotopic and ultratrace analysis of uranium by double-focusing sector field ICP mass spectrometry [J].
Kerl, W ;
Becker, JS ;
Dietze, HJ ;
Dannecker, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :407-409
[4]   Double-focusing mass spectrometers in ICPMS [J].
Moens, L ;
Jakubowski, N .
ANALYTICAL CHEMISTRY, 1998, 70 (07) :251A-256A
[5]   Determination of trace metals in estuarine and sea-water reference materials by high resolution inductively coupled plasma mass spectrometry [J].
Rodushkin, I ;
Ruth, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) :1181-1185
[6]   ISOTOPIC RATIO MEASUREMENTS WITH AN INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETER [J].
RUSS, GP ;
BAZAN, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) :49-62
[7]  
SCHROEDER E, 1999, WINT PLASM C JAN 10
[8]   Measurements of Ca-44:Ca-43 and Ca-42:Ca-43 isotopic ratios in urine using high resolution inductively coupled plasma mass spectrometry [J].
Sturup, S ;
Hansen, M ;
Molgaard, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :919-923
[9]   Dependence of detector dead time on analyte mass number in inductively coupled plasma mass spectrometry [J].
Vanhaecke, F ;
de Wannemacker, G ;
Moens, L ;
Dams, R ;
Latkoczy, C ;
Prohaska, T ;
Stingeder, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (06) :567-571
[10]   Precise measurement of isotope ratios with a double-focusing magnetic sector ICP mass spectrometer [J].
Vanhaecke, F ;
Moens, L ;
Dams, R ;
Taylor, P .
ANALYTICAL CHEMISTRY, 1996, 68 (03) :567-569