protein bead array (PBA); suspension array technology (SAT); hybrid flow cytometry; microfluorospheres; multitasking platform;
D O I
10.1002/cyto.b.20109
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: A new generation of bench-top flow cytometers with digital signal processing to perform suspension array technology (SAT) based bead array assays as well as leukocyte immunophenotyping is now available. These hybrid instruments provide an opportunity for the development of a more cost effective multitasking platform to support infectious disease treatment in resource limited countries. Methods: We report the development and testing of two modules compatible with the hybrid flow cytometers. The first module is an eleven HIV-1 protein bead array (PBA) for the detection of circulating antibodies and the second is a cell based T-cell enumeration assay. Results: The HIV-1 PBA was tested in parallel with two enzyme immunoassays (EIAs) for the detection of plasma antibodies from 4 HIV-1 seroconversion panels and a low antibody titer panel. The PBA as well as the two EIAs performed equally for the detection of antibody positive samples from all seroconversion panels. One antibody positive sample from the low antibody titer panel was missed by the PBA together with one of the two EIAs tested. A parallel analysis of the HIV-1 PBA with Western blot (a confirmatory test for HIV infection) using plasma from nine HIV-1(+) individuals showed that the HIV-1 PBA detected more of the gp41 and gp120 antibody positive samples. Preliminary CD4 T-cell immunophenotyping results from 14 HIV(+) and 10 HIV(+) whole blood specimens with the hybrid flow cytometer platform compared well to conventional flow cytometry data. Conclusion: The successful combination of bead and cell based assays on a single hybrid instrument demonstrated the potential utility of a multitasking platform. The results presented are providing groundwork for future development of more cost effective modular architecture for a flexible flow cytometry based platform. (c) 2006 international Society for Analytical Cytology.
引用
收藏
页码:179 / 188
页数:10
相关论文
共 37 条
[1]  
Bellisario R, 2000, CLIN CHEM, V46, P1422
[2]   Simultaneous measurement of antibodies to three HIV-1 antigens in newborn dried blood-spot specimens using a multiplexed microsphere-based immunoassay [J].
Bellisario, R ;
Colinas, RJ ;
Pass, KA .
EARLY HUMAN DEVELOPMENT, 2001, 64 (01) :21-25
[3]  
Benecky MJ, 1998, CLIN CHEM, V44, P2052
[4]   Development of multiplexed fluorescence microbead covalent assays (FMCAs) for pesticide biomonitoring [J].
Biagini, RE ;
Murphy, DM ;
Sammons, DL ;
Smith, JP ;
Striley, CAF ;
MacKenzie, BA .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2002, 68 (04) :470-477
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Detection of epitope-tagged proteins in flow cytometry: Fluorescence resonance energy transfer-based assays on beads with femtomole resolution [J].
Buranda, T ;
Lopez, GP ;
Simons, P ;
Pastuszyn, A ;
Sklar, LA .
ANALYTICAL BIOCHEMISTRY, 2001, 298 (02) :151-162
[7]   RELIABLE CONFIRMATION AND QUANTITATION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 ANTIBODY USING A RECOMBINANT-ANTIGEN IMMUNOBLOT ASSAY [J].
BUSCH, MP ;
ELAMAD, Z ;
MCHUGH, TM ;
CHIEN, D ;
POLITO, AJ .
TRANSFUSION, 1991, 31 (02) :129-137
[8]   Flow cytometry-based minisequencing: A new platform for high-throughput single-nucleotide polymorphism scoring [J].
Cai, H ;
White, PS ;
Torney, D ;
Deshpande, A ;
Wang, ZL ;
Marrone, B ;
Nolan, JP .
GENOMICS, 2000, 66 (02) :135-143
[9]   RISK-FACTORS FOR REPEATEDLY REACTIVE HIV-1 EIA AND INDETERMINATE WESTERN BLOTS - A POPULATION-BASED CASE-CONTROL STUDY [J].
CELUM, CL ;
COOMBS, RW ;
JONES, M ;
MURPHY, V ;
FISHER, L ;
GRANT, C ;
COREY, L ;
INUI, T ;
WENER, MH ;
HOLMES, KK .
ARCHIVES OF INTERNAL MEDICINE, 1994, 154 (10) :1129-1137
[10]   A microsphere-based assay for multiplexed single nucleotide polymorphism analysis using single base chain extension [J].
Chen, JW ;
Iannone, MA ;
Li, MS ;
Taylor, JD ;
Rivers, P ;
Nelsen, AJ ;
Slentz-Kesler, KA ;
Roses, A ;
Weiner, MP .
GENOME RESEARCH, 2000, 10 (04) :549-557