Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques

被引:152
作者
Fulkerson, E
Egol, KA
Kubiak, EN
Liporace, F
Kummer, FJ
Koval, KJ
机构
[1] Hosp Joint Dis & Med Ctr, Dept Orthopaed Surg, New York, NY 10003 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Orthopaed Surg, Lebanon, NH 03766 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2006年 / 60卷 / 04期
关键词
locked compression plating; dynamic compression plating; ulna; comminuted fracture; osteoporosis;
D O I
10.1097/01.ta.0000195462.53525.0c
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Locking plates are an alternative to conventional compression plate fixation for diaphyseal fractures. The objective of this study was to compare the stability of various plating with locked screw constructs to conventional nonlocked screws for fixation of a comminuted diaphyseal fracture model using a uniform, synthetic ulna. Locked screw construct variables were the use of unicortical or bicortical screws, and increasing bone to plate distance. Methods: This biomechanical study compared various construct groups after cyclic axial loading and three-point bending. Results were analyzed via one-way analysis of variance. Displacements after cyclical axial loading and number of cycles to failure in cyclic bending were used to assess construct stability. Results: The constructs fixed by plates with bicortical locked screws withstood significantly more cycles to failure than the other constructs (p < 0.001). Significantly less displacement occurred after axial loading with bicortical locked screws than with bicortical nonlocked screws. Increased distance of the plate from the bone surface, and use of unicortical locked screws led to early failure with cyclic loading for constructs with locked screws. Conclusions: These results support the use of plating with bicortical locked screws as an alternative to conventional plating for comminuted diaphyseal fractures in osteoporotic bone. Bicortical locked screws with minimal displacement from the bone surface provide the most stable construct in the tested synthetic comminuted diaphyseal fracture model. The results of this study suggest use of plates with unicortical screws for the described fracture is not recommended.
引用
收藏
页码:830 / 835
页数:6
相关论文
共 12 条
[1]  
Ansell R H, 1968, J Biomech, V1, P279, DOI 10.1016/0021-9290(68)90023-7
[2]   Cancellous bone screw thread design and holding power [J].
Asnis, SE ;
Ernberg, JJ ;
Bostrom, MPG ;
Wright, TM ;
Harrington, RM ;
Tencer, A ;
Peterson, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (07) :462-469
[3]  
BURSTEIN AH, 1994, FUNDAMENTAL ORTHOPAE
[4]  
DeCoster T A, 1990, J Orthop Trauma, V4, P169, DOI 10.1097/00005131-199004020-00012
[5]  
Gautier E, 1992, CURR ORTHOP, V6, P220
[6]   Plate osteosynthesis of diaphyseal fractures of the radius and ulna [J].
Hertel, R ;
Pisan, M ;
Lambert, S ;
Ballmer, FT .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (08) :545-548
[7]   LONG-BONE TORSION .1. EFFECTS OF HETEROGENEITY, ANISOTROPY AND GEOMETRIC IRREGULARITY [J].
KENNEDY, JG ;
CARTER, DR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (02) :183-188
[8]   REFRACTURES - A CONSEQUENCE OF IMPAIRED LOCAL BONE VIABILITY [J].
KESSLER, SB ;
DEILER, S ;
SCHIFFLDEILER, M ;
UHTHOFF, HK ;
SCHWEIBERER, L .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 111 (02) :96-101
[9]   Radioulnar load-sharing in the forearm - A study in cadavera [J].
Markolf, KL ;
Lamey, D ;
Yang, S ;
Meals, R ;
Hotchkiss, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :879-888
[10]  
Ross J. W., 1999, IT Professional, V1, P65, DOI 10.1109/6294.781626