Tip motion in amplitude modulation (tapping-mode) atomic-force microscopy:: Comparison between continuous and point-mass models

被引:152
作者
Rodríguez, TR [1 ]
García, R [1 ]
机构
[1] CSIC, Inst Microelect Madrid, Madrid 28760, Spain
关键词
D O I
10.1063/1.1456543
中图分类号
O59 [应用物理学];
学科分类号
摘要
We discuss the influence of high-order frequency components in the operation of an amplitude modulation atomic-force microscope (AFM). A comparative study of point-mass and continuous models is performed to describe the tip motion. The tip-surface interaction force excites high-order frequency components whenever a higher harmonic of the excitation force is close to an eigenmode of the cantilever beam. The strength of those components depends on the set point amplitude and the fundamental resonance frequency of the cantilever. However, for standard operating conditions with quality factors in the 10(2)-10(3) range, higher-order components are about three orders of magnitude smaller than the component at the excitation frequency. We conclude that point-mass models are suitable to describe the operation of a tapping-mode AFM in air environments. (C) 2002 American Institute of Physics.
引用
收藏
页码:1646 / 1648
页数:3
相关论文
共 16 条
[1]  
[Anonymous], 1981, THEORY ELASTICITY
[2]   CALCULATION OF THERMAL NOISE IN ATOMIC-FORCE MICROSCOPY [J].
BUTT, HJ ;
JASCHKE, M .
NANOTECHNOLOGY, 1995, 6 (01) :1-7
[3]   Energy dissipation in tapping-mode atomic force microscopy [J].
Cleveland, JP ;
Anczykowski, B ;
Schmid, AE ;
Elings, VB .
APPLIED PHYSICS LETTERS, 1998, 72 (20) :2613-2615
[4]   Dynamics of a vibrating tip near or in intermittent contact with a surface [J].
García, R ;
San Paulo, A .
PHYSICAL REVIEW B, 2000, 61 (20) :13381-13384
[5]   Attractive and repulsive tip-sample interaction regimes in tapping-mode atomic force microscopy [J].
García, R ;
San Paulo, A .
PHYSICAL REVIEW B, 1999, 60 (07) :4961-4967
[6]   Conservative and dissipative tip-sample interaction forces probed with dynamic AFM [J].
Gotsmann, B ;
Seidel, C ;
Anczykowski, B ;
Fuchs, H .
PHYSICAL REVIEW B, 1999, 60 (15) :11051-11061
[7]   Higher-harmonics generation in tapping-mode atomic-force microscopy: Insights into the tip-sample interaction [J].
Hillenbrand, R ;
Stark, M ;
Guckenberger, R .
APPLIED PHYSICS LETTERS, 2000, 76 (23) :3478-3480
[8]   Study of water droplets and films on graphite by noncontact scanning force microscopy [J].
Luna, M ;
Colchero, J ;
Baró, AM .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (44) :9576-9581
[9]   A unifying view on some experimental effects in tapping-mode atomic force microscopy [J].
Marth, M ;
Maier, D ;
Honerkamp, J ;
Brandsch, R ;
Bar, G .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (10) :7030-7036
[10]   Nonlinear dynamical properties of an oscillating tip-cantilever system in the tapping mode [J].
Nony, L ;
Boisgard, R ;
Aimé, JP .
JOURNAL OF CHEMICAL PHYSICS, 1999, 111 (04) :1615-1627