Highly sensitive detection of pathogen Escherichia coli O157:H7 by electrochemical impedance spectroscopy

被引:135
作者
Barreiros dos Santos, M. [1 ,2 ,3 ]
Agusil, J. P. [1 ,3 ]
Prieto-Simon, B. [1 ,3 ]
Sporer, C. [1 ,3 ]
Teixeira, V. [4 ]
Samitier, J. [1 ,3 ,5 ]
机构
[1] Inst Bioengn Catalonia IBEC, Nanobioengn Grp, Barcelona 08028, Spain
[2] Int Iberian Nanotechnol Lab INL, P-4704310 Braga, Portugal
[3] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CI, Zaragoza 50018, Spain
[4] Univ Minho, Dept Phys, P-4800058 Guimaraes, Portugal
[5] Univ Barcelona, Dept Elect, E-08028 Barcelona, Spain
关键词
Biosensors; Immunosensor; Electrochemical impedance spectroscopy; Bacteria detection; Enterohemorrhagic E. coli O157:H7; SURFACE-PLASMON RESONANCE; SELF-ASSEMBLED MONOLAYER; IN-GROUND BEEF; RAPID DETECTION; O157-H7; IMMUNOSENSOR; BIOSENSORS; BACTERIA; FOOD; PCR;
D O I
10.1016/j.bios.2013.01.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The presence of enterohemorrhagic Escherichia coli bacteria in food can cause serious foodborne disease outbreaks. Early detection and identification of these pathogens is extremely important for public health and safety. Here we present a highly sensitive label-free immunosensor for the detection of pathogenic E. coli O157:H7. Anti-E. coli antibodies were covalently immobilised onto gold electrodes via a self-assembled monolayer (SAM) of mercaptohexadecanoic acid and the pathogenic bacteria were detected by electrochemical impedance spectroscopy (EIS). Surface Plasmon Resonance (SPR) was used to monitor the antibody immobilisation protocol and antibody patterned surfaces were used to demonstrate the specificity of the antibody coated surfaces against the pathogenic bacteria. The immunosensor showed a very low limit of detection (2 CFU/mL) and a large linear range (3 x 10-3 X 10(4) CFU/mL). Finally, the selectivity of the sensor was demonstrated and no significant adsorption of Salmonella typhimurium was observed. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 47 条
[41]   New Trends in Impedimetric Biosensors for the Detection of Foodborne Pathogenic Bacteria [J].
Wang, Yixian ;
Ye, Zunzhong ;
Ying, Yibin .
SENSORS, 2012, 12 (03) :3449-3471
[42]  
World Health Organization, 2007, FOOD SAF FOODB ILLN
[43]  
World Health Organization, 2011, EHEC OUTBR INCR CAS
[44]   Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria [J].
Yang, Liju ;
Bashir, Rashid .
BIOTECHNOLOGY ADVANCES, 2008, 26 (02) :135-150
[45]   AFM and impedance spectroscopy characterization of the immobilization of antibodies on indium-tin oxide electrode through self-assembled monolayer of epoxysilane and their capture of Escherichia coli O157:H7 [J].
Yang, LJ ;
Li, YB .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (07) :1407-1416
[46]   Interdigitated array microelectrode-based electrochemical impedance immunosensor for detection of Escherichia coli O157:H7 [J].
Yang, LJ ;
Li, YB ;
Erf, GF .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1107-1113
[47]  
Zhang D., 2005, IEEE ENG MED BIOL SO, V7, P7111