Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?

被引:41
作者
Hudelmaier, M
Kuhn, V
Lochmüller, EM
Well, H
Priemel, M
Link, TM
Eckstein, F
机构
[1] LMU Munchen, Inst Anat, Musculoskeletal Res Grp, D-80336 Munich, Germany
[2] Paracelsus Private Med Univ, Inst Anat, Salzburg, Austria
[3] LMU Munchen, Gynaecol Hosp 1, Munich, Germany
[4] Univ Hamburg, Sch Med, Dept Trauma Surg, Hamburg, Germany
[5] Tech Univ Munich, Dept Radiol, D-8000 Munich, Germany
关键词
cortical bone; dual X-ray absorptiometry; mechanical competence; peripheral quantitative CT; quantitative ultrasound; trabecular bone;
D O I
10.1007/s00198-003-1551-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The diagnosis of osteoporosis is generally based on the assessment of bone mineral content with dual X-ray absorptiometry (DXA) but does not account for the spatial distribution and inherent material properties of the tissue. Peripheral quantitative computed tomography (pQCT) permits one to measure the compartment-specific density and geometry-based parameters of cortical bone. Quantitative ultrasound (QUS) parameters are associated with material properties of cortical bone. The purpose of this study was to test the hypothesis that pQCT and cortical QUS provide additional information to DXA in predicting structural strength of the distal radius. The intact right arm and the isolated left radius were harvested from 70 formalin-fixed cadavers (age 79+/-11 years). The bone mineral content (BMC) was assessed with DXA at the radial metaphysis and shaft. pQCT was also used at the metaphysis and the shaft, while QUS was employed only at the shaft. The failure loads of the radius were assessed by use of a 3-point bending test (isolated radius) and a complex fall simulation (intact arm). The BMC (DXA) displayed a correlation of r=0.96 with the failure moments in 3-point bending (P<0.001). The correlation between failure load and geometry-based parameters (pQCT) ranged from r=0.85 to r=0.96 and was r=0.64 for the speed of sound (QUS) (P <0.001). Cortical thickness (pQCT) improved the prediction marginally (r=0.964) in combination with DXA. For the fall simulation, the correlation coefficients were r=0.76 for BMC (DXA) of the shaft, r=0.83 for metaphyseal bone content (pQCT), r=0.55 for QUS, and ranged from r=0.59 to r=0.74 for geometry-based parameters at the shaft (pQCT). pQCT and QUS parameters provided no significant improvement versus DXA alone. Measurement of bone mass by DXA or pQCT thus appears to be sufficient as a surrogate of mechanical strength and fracture risk of the distal radius.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 22 条
[1]   Distal radius fractures: Mechanisms of injury and strength prediction by bone mineral assessment [J].
Augat, P ;
Iida, H ;
Jiang, YB ;
Diao, E ;
Genant, HK .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (05) :629-635
[2]   A new method for quantitative ultrasound measurements at multiple skeletal sites -: First Results of precision and fracture discrimination [J].
Barkmann, R ;
Kantorovich, E ;
Singal, C ;
Hans, D ;
Genant, HK ;
Heller, M ;
Glüer, CC .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (01) :1-7
[3]   Forearm fractures as predictors of subsequent osteoporotic fractures [J].
Cuddihy, MT ;
Gabriel, SE ;
Crowson, CS ;
O'Fallon, WM ;
Melton, LJ .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (06) :469-475
[4]   FORMALIN FIXATION EFFECTS ON VERTEBRAL BONE-DENSITY AND FAILURE MECHANICS - AN IN-VITRO STUDY OF HUMAN AND SHEEP VERTEBRAE [J].
EDMONDSTON, SJ ;
SINGER, KP ;
DAY, RE ;
BREIDAHL, PD ;
PRICE, RI .
CLINICAL BIOMECHANICS, 1994, 9 (03) :175-179
[5]   Comparative assessment of bone mineral measurements using dual x-ray absorptiometry and peripheral quantitative computed tomography [J].
Formica, CA ;
Nieves, JW ;
Cosman, F ;
Garrett, P ;
Lindsay, R .
OSTEOPOROSIS INTERNATIONAL, 1998, 8 (05) :460-467
[6]   Quantitative ultrasound and bone densitometry to evaluate the risk of nonspine fractures: A prospective study [J].
Gnudi, S ;
Ripamonti, C ;
Malavolta, N .
OSTEOPOROSIS INTERNATIONAL, 2000, 11 (06) :518-523
[7]   Precision and intersite correlation of bone densitometry at the radius, tibia and femur with peripheral quantitative CT [J].
Groll, O ;
Lochmüller, EM ;
Bachmeier, M ;
Willnecker, J ;
Eckstein, F .
SKELETAL RADIOLOGY, 1999, 28 (12) :696-702
[8]  
GUGLIEMI G, 1997, EUR RADIOL, V7, P32
[9]   Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture? [J].
Hans, D ;
Srivastav, SK ;
Singal, C ;
Barkmann, R ;
Njeh, CF ;
Kantorovich, E ;
Glüer, CC ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (04) :644-651
[10]  
Hayes Wilson C., 1997, P69