Calibration and validation of a voxel phantom for use in the Monte Carlo modeling and optimisation of X-ray imaging systems

被引:10
作者
Dance, DR [1 ]
McVey, G [1 ]
Sadborg, M [1 ]
Persliden, J [1 ]
Carlsson, GA [1 ]
机构
[1] Royal Marsden NHS Trust, Dept Phys, London SW3 6JJ, England
来源
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 1999年 / 3659卷
关键词
Monte Carlo modeling; voxel phantom; patient dose; image quality; chest; lumbar spine;
D O I
10.1117/12.349533
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Monte Carlo program has been developed to model X-ray imaging systems. It incorporates an adult voxel phantom and includes anti-scatter grid, radiographic screen and film. The program can calculate contrast and noise for a series of anatomical details. The use of measured H and D curves allows the absolute calculation of the patient entrance air kerma for a given film optical density (or vice versa). Effective dose can also be estimated. In an initial validation, the program was used to predict the optical density for exposures with, plastic slabs of various thicknesses. The agreement between measurement and calculation was on average within 5%. In a second validation, a comparison was made between computer simulations and measurements for chest and lumbar spine patient radiographs. The predictions of entrance air kerma mostly fell within the range of measured values (e.g. chest PA calculated. 0.15 mGy, measured 0.12-0.17 mGy). Good agreement was also obtained for the calculated and measured contrasts for selected anatomical details and acceptable agreement for dynamic range. It is concluded that the program provides a realistic;model of the patient and imaging system. It can thus form the basis of a detailed study and optimization of X-ray imaging systems.
引用
收藏
页码:548 / 559
页数:12
相关论文
共 16 条
[1]  
[Anonymous], 1991, ANN ICRP, V60
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]  
CARMICHAEL JH, 1996, 16260E EN EUR
[4]   The use of carbon fibre material in radiographic cassettes: Estimation of the dose and contrast advantages [J].
Dance, DR ;
Lester, SA ;
Carlsson, GA ;
Sandborg, M ;
Persliden, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (832) :383-390
[5]  
HART D, 1994, NRPBR262
[6]  
ICRU, 1992, ICRU Report, P46
[7]  
ICRU, 1992, 48 ICRU
[8]  
International Commission on Radiological Protection, 1975, REPORT TASK GROUP RE
[9]  
Jones D G., 1985, NRPBR186
[10]  
KRAMER R, 1979, S556 GSF