Finite element modeling of endovascular coiling and flow diversion enables hemodynamic prediction of complex treatment strategies for intracranial aneurysm

被引:70
作者
Damiano, Robert J. [1 ,2 ]
Ma, Ding [1 ,2 ]
Xiang, Jianping [2 ,3 ]
Siddiqui, Adnan H. [2 ,3 ,5 ]
Snyder, Kenneth V. [2 ,3 ,5 ]
Meng, Hui [1 ,2 ,3 ,4 ]
机构
[1] SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY 14203 USA
[2] SUNY Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY 14203 USA
[3] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14203 USA
[4] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY 14203 USA
[5] SUNY Buffalo, Dept Radiol, Buffalo, NY 14203 USA
基金
美国国家卫生研究院;
关键词
Treatment outcome; Flow diverter; Flow diverter with adjunctive coils; Virtual stenting; Virtual coiling; PIPELINE EMBOLIZATION DEVICE; CEREBRAL ANEURYSMS; IN-VITRO; SIMULATION; DEPLOYMENT; PACKING;
D O I
10.1016/j.jbiomech.2015.06.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Endovascular interventions using coil embolization and flow diversion are becoming the mainstream treatment for intracranial aneurysms (IAs). To help assess the effect of intervention strategies on aneurysm hemodynamics and treatment outcome, we have developed a finite-element-method (FEM)-based technique for coil deployment along with our HiFiVS technique for flow diverter (FD) deployment in patient-specific IAs. We tested four clinical intervention strategies: coiling (1-8 coils), single FD, FD with adjunctive coils (1-8 coils), and overlapping FDs. By evaluating post-treatment hemodynamics using computational fluid dynamics (CFD), we compared the flow-modification performance of these strategies. Results show that a single FD provides more reduction in inflow rate than low packing density (PD) coiling, but less reduction in average velocity inside the aneurysm. Adjunctive coils add no additional reduction of inflow rate beyond a single FD until coil PD exceeds 11%. This suggests that the main role of FDs is to divert inflow, while that of coils is to create stasis in the aneurysm. Overlapping FDs decreases inflow rate, average velocity, and average wall shear stress (WSS) in the aneurysm sac, but adding a third FD produces minimal additional reduction. In conclusion, our FEM-based techniques for virtual coiling and flow diversion enable recapitulation of complex endovascular intervention strategies and detailed hemodynamics to identify hemodynamic factors that affect treatment outcome. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3332 / 3340
页数:9
相关论文
共 27 条
[1]
Simulation of intracranial aneurysm stenting: Techniques and challenges [J].
Appanaboyina, Sunil ;
Mut, Fernando ;
Loehner, Rainald ;
Putman, Christopher ;
Cebral, Juan .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2009, 198 (45-46) :3567-3582
[2]
Finite element modeling of embolic coil deployment: Multifactor characterization of treatment effects on cerebral aneurysm hemodynamics [J].
Babiker, M. Haithem ;
Chong, Brian ;
Gonzalez, L. Fernando ;
Cheema, Sachmanik ;
Frakes, David H. .
JOURNAL OF BIOMECHANICS, 2013, 46 (16) :2809-2816
[3]
An In Vitro Study of Pulsatile Fluid Dynamics in Intracranial Aneurysm Models Treated with Embolic Coils and Flow Diverters [J].
Babiker, M. Haithem ;
Gonzalez, L. Fernando ;
Albuquerque, Felipe ;
Collins, Daniel ;
Elvikis, Arius ;
Zwart, Christine ;
Roszelle, Breigh ;
Frakes, David H. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) :1150-1159
[4]
Estimating the proportion of intracranial aneurysms likely to be amenable to treatment with the pipeline embolization device [J].
Brinjikji, Waleed ;
Cloft, Harry J. ;
Fiorella, David ;
Lanzino, Giuseppe ;
Kallmes, David F. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 (01) :45-48
[5]
Byrne JV., 2012, EJMINT ORIG ARTIC, V1225000057, P1
[6]
CFD modeling of blood flow following coil embolization of aneurysms [J].
Byun, HS ;
Rhee, K .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) :755-761
[7]
Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique [J].
Cebral, JR ;
Löhner, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :468-476
[8]
Aneurysm Rupture after Endovascular Flow Diversion: the Possible Role of Persistent Flows through the Transition Zone Associated with Device Deformation [J].
Darsaut, T. E. ;
Rayner-Hartley, E. ;
Makoyeva, A. ;
Salazkin, I. ;
Berthelet, F. ;
Raymond, J. .
INTERVENTIONAL NEURORADIOLOGY, 2013, 19 (02) :180-185
[9]
Dequidt J, 2008, LECT NOTES COMPUT SC, V5241, P695, DOI 10.1007/978-3-540-85988-8_83
[10]
A Paradigm-Shifting Technology for the Treatment of Cerebral Aneurysms: The Pipeline Embolization Device [J].
Dumont, Travis M. ;
Mokin, Maxim ;
Snyder, Kenneth V. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Hopkins, L. Nelson, III .
WORLD NEUROSURGERY, 2013, 80 (06) :800-803