An abdominal aortic aneurysm segmentation method: Level set with region and statistical information

被引:53
作者
Zhuge, Feng [1 ]
Rubin, Geoffrey D.
Sun, Shaohua
Napel, Sandy
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
abdominal aortic aneurysm; deformable model; CT angiography;
D O I
10.1118/1.2193247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a system for segmenting the human aortic aneurysm in CT angiograms (CTA), which, in turn, allows measurements of volume and morphological aspects useful for treatment planning The system estimates a rough "initial surface," and then refines it using a level set segmentation scheme augmented with two external analyzers: The global region analyzer, which incorporates a priori knowledge of the intensity, volume, and shape of the aorta and other structures, and the local feature analyzer, which uses voxel location, intensity, and texture features to train and drive a support vector machine classifier. Each analyzer outputs a value that corresponds to the likelihood that a given voxel is part of the aneurysm, which is used during level set iteration to control the evolution of the surface. We tested our system using a database of 20 CTA scans of patients with aortic aneurysms. The mean and worst case values of volume overlap, volume error, mean distance error, and maximum distance error relative to human tracing were 95.3%+/- 1.4% (s.d.);worst case=92.9%, 3.5%+/- 2.5% (s.d.); worstcase=7.0%, 0.6 +/- 0.2mm (s.d.); worstcase =1.0 mm, and 5.2 +/- 2.3mm (s.d.); worstcase=9.6 mm, respectively. When implemented on a 2.8 GHz Pentium IV personal computer, the mean time required for segmentation was 7.4 +/- 3.6min (s.d.). We also performed experiments that suggest that our method is insensitive to parameter changes within 10% of their experimentally determined values. This preliminary study proves feasibility for an accurate, precise, and robust system for segmentation of the abdominal aneurysm from CTA data, and may be of benefit to patients with aortic aneurysms. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1440 / 1453
页数:14
相关论文
共 58 条
[51]  
SURI JS, 2001, INT J ENG MED BIOL, V20
[52]  
Toledo R, 2000, PROC CVPR IEEE, P157, DOI 10.1109/CVPR.2000.855814
[53]  
Vapnik V., 1998, STAT LEARNING THEORY, V1, P2
[54]   Imaging of abdominal aortic aneurysm before and after endoluminal stent-graft repair [J].
Whitaker, SC .
EUROPEAN JOURNAL OF RADIOLOGY, 2001, 39 (01) :3-15
[55]   Snakes, shapes, and gradient vector flow [J].
Xu, CY ;
Prince, JL .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1998, 7 (03) :359-369
[56]  
Yoo T.S, 2004, INSIGHT IMAGES
[57]  
Yoo TS, 2002, STUD HEALTH TECHNOL, V85, P586
[58]   Segmentation and measurement of the cortex from 3-D MR images using coupled-surfaces propagation [J].
Zeng, XL ;
Staib, LH ;
Schultz, RT ;
Duncan, JS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :927-937