Compact soft x-ray transmission microscopy with sub-50 nm spatial resolution

被引:51
作者
Kim, KW
Kwon, Y
Nam, KY
Lim, JH
Kim, KG
Chon, KS
Kim, BH
Kim, DE
Kim, J
Ahn, BN
Shin, HJ
Rah, S
Kim, KH
Chae, JS
Gweon, DG
Kang, DW
Kang, SH
Min, JY
Choi, KS
Yoon, SE
Kim, EN
Namba, Y
Yoon, KH
机构
[1] Wonkwang Univ, Sch Med, Dept Radiol, Iksan 570749, Jeonbuk, South Korea
[2] Wonkwang Univ, Sch Med, Inst Radiol Imaging Sci, Iksan 570749, Jeonbuk, South Korea
[3] Pohang Univ Sci & Technol, Dept Phys, Pohang, South Korea
[4] Vacuum & Measurement Technol Co Ltd, Pohang 790320, South Korea
[5] POSTECH, Pohang Accelerator Lab, Pohang 79020, South Korea
[6] Korea Elect Opt Co Ltd, Puchon 421150, South Korea
[7] Korea Adv Inst Sci & Technol, Dept Mech Engn, Taejon 305701, South Korea
[8] LISTEM Co Ltd, Inchon 403032, South Korea
[9] Chubu Univ, Dept Mech Engn, Aichi 4878501, Japan
关键词
D O I
10.1088/0031-9155/51/6/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, the development of compact transmission soft x-ray microscopy (XM) with sub-50 nm spatial resolution for biomedical applications is described. The compact transmission soft x-ray microscope operates at lambda = 2.88 nm (430 eV) and is based on a tabletop regenerative x-ray source in combination with a tandem ellipsoidal condenser mirror for sample illumination, an objective micro zone plate and a thinned back-illuminated charge coupled device to record an x-ray image. The new, compact x-ray microscope system requires the fabrication of proper x-ray optical devices in order to obtain high-quality images. For an application-oriented microscope, the alignment procedure is fully automated via computer control through a graphic user interface. In imaging studies using Our compact XM system, a gold mesh image was obtained with 45 nm resolution at x580 magnification and 1 min exposure. Images of a biological sample (Coscinodiscus oculoides) were recorded.
引用
收藏
页码:N99 / N107
页数:9
相关论文
共 13 条
[1]  
Abraham-Peskir J, 1998, MED SCI RES, V26, P663
[2]  
Berglund M, 2000, J MICROSC-OXFORD, V197, P268, DOI 10.1046/j.1365-2818.2000.00675.x
[3]   Soft X-ray microscopy at a spatial resolution better than 15nm [J].
Chao, WL ;
Harteneck, BD ;
Liddle, JA ;
Anderson, EH ;
Attwood, DT .
NATURE, 2005, 435 (7046) :1210-1213
[4]   A characterisation of dark-field imaging of colloidal gold labels in a scanning transmission X-ray microscope [J].
Chapman, HN ;
Jacobsen, C ;
Williams, S .
ULTRAMICROSCOPY, 1996, 62 (03) :191-213
[5]   X-RAY LASER MICROSCOPY OF RAT SPERM NUCLEI [J].
DASILVA, LB ;
TREBES, JE ;
BALHORN, R ;
MROWKA, S ;
ANDERSON, E ;
ATTWOOD, DT ;
BARBEE, TW ;
BRASE, J ;
CORZETT, M ;
GRAY, J ;
KOCH, JA ;
LEE, C ;
KERN, D ;
LONDON, RA ;
MACGOWAN, BJ ;
MATTHEWS, DL ;
STONE, G .
SCIENCE, 1992, 258 (5080) :269-271
[6]   Fabrication and testing of Wolter type-I mirrors for soft x-ray microscopes [J].
Hoshino, M ;
Aoki, S ;
Watanabe, N ;
Hirai, S .
ADVANCES IN MIRROR TECHNOLOGY FOR X-RAY, EUV LITHOGRAPHY, LASER, AND OTHER APPLICATIONS II, 2004, 5533 :85-92
[7]   Soft x-ray microscopy [J].
Jacobsen, C .
TRENDS IN CELL BIOLOGY, 1999, 9 (02) :44-47
[8]   Design and performance of a laser-plasma-based compact soft x-ray microscope [J].
Johansson, GA ;
Holmberg, A ;
Hertz, HM ;
Berglund, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03) :1193-1197
[9]   SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS [J].
KIRZ, J ;
JACOBSEN, C ;
HOWELLS, M .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) :33-130
[10]   Intracellular structures of normal and aberrant Plasmodium falciparum malaria parasites imaged by soft x-ray microscopy [J].
Magowan, C ;
Brown, JT ;
Liang, J ;
Heck, J ;
Coppel, RL ;
Mohandas, N ;
MeyerIlse, W .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (12) :6222-6227