A simple and efficient approach to reversed-phase HPLC method screening

被引:23
作者
Biswas, Kallol M. [1 ]
Castle, Bryan C. [1 ]
Olsen, Bernard A. [1 ]
Risley, Donald S. [1 ]
Skibic, Michael J. [1 ]
Wright, Paul B. [1 ]
机构
[1] Eli Lilly & Co, Lilly Res Labs, Indianapolis, IN 46285 USA
关键词
HPLC; Method screening; Column; Strategy; Pharmaceutical; PERFORMANCE LIQUID-CHROMATOGRAPHY; COLUMN SELECTIVITY; SEPARATION; CLASSIFICATION; SYSTEM;
D O I
10.1016/j.jpba.2008.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development and utility of an efficient HPLC method screening strategy using only four columns for the separation of pharmaceutical compounds and related impurities is presented. The strategy established a two-column approach to enable rapid early method development, along with a four-column approach for commercial method development of the analytical methods utilized to verify the quality of drug substance or drug product. Mobile phases consisted of acetonitrile or methanol with aqueous trifluoroacetic acid for low pH screening, and ammonium hydroxide for high pH screening. Examples are provided to demonstrate the practicality and orthogonality of the method screening process. A unique system suitability check, using commercially available compounds, was incorporated as a tool for troubleshooting and for ensuring adequate system performance prior to screening. Initial testing of the strategy revealed that the columns chosen were successful in leading to assay and impurity methods for 40 pharmaceutical compounds. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:692 / 701
页数:10
相关论文
共 16 条
[1]   Comparative characteristics of HPLC columns based on quantitative structure-retention relationships (QSRR) and hydrophobic-subtraction model [J].
Baczek, T ;
Kaliszan, R ;
Novotná, K ;
Jandera, P .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :109-115
[2]   Retention of ionizable compounds on high-performance liquid chromatography -: III.: Variation of pK values of acids and pH values of buffers in acetonitrile-water mobile phases [J].
Bosch, E ;
Espinosa, S ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :137-146
[3]   Variability of column selectivity for reversed-phase high-performance liquid chromatography - Compensation by adjustment of separation conditions [J].
Dolan, JW ;
Snyder, LR ;
Jupille, TH ;
Wilson, NS .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :51-67
[4]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns using principal component analysis [J].
Euerby, M ;
Petersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 994 (1-2) :13-36
[5]   Column selectivity in reversed-phase liquid chromatography - IV. Type-B alkyl-silica columns [J].
Gilroy, JJ ;
Dolan, JW ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :757-778
[6]   Development of some stationary phases for reversed-phase high-performance liquid chromatography [J].
Kirkland, JJ .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :9-21
[7]   Application of a column selection system and DryLab software for high-performance liquid chromatography method development [J].
Krisko, Ryan M. ;
McLaughlin, Kieran ;
Koenigbauer, Michael J. ;
Lunte, Craig E. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) :186-193
[8]   EFFECTS OF ANIONS ON THE POSITIVE-ION ELECTROSPRAY-IONIZATION MASS-SPECTRA OF PEPTIDES AND PROTEINS [J].
MIRZA, UA ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2898-2904
[9]   Orthogonal separations for reversed-phase liquid chromatography [J].
Pellett, J ;
Lukulay, P ;
Mao, Y ;
Bowen, W ;
Reed, R ;
Ma, M ;
Munger, RC ;
Dolan, JW ;
Wrisley, L ;
Medwid, K ;
Toltl, NP ;
Chan, CC ;
Skibic, M ;
Biswas, K ;
Wells, KA ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :122-135
[10]   Orthogonality and similarity within silica-based reversed-phased chromatographic systems [J].
Van Gyseghem, E ;
Jimidar, M ;
Sneyers, R ;
Redlich, D ;
Verhoeven, E ;
Massart, DL ;
Vander Heyden, Y .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1074 (1-2) :117-131