Orthogonality and similarity within silica-based reversed-phased chromatographic systems

被引:45
作者
Van Gyseghem, E
Jimidar, M
Sneyers, R
Redlich, D
Verhoeven, E
Massart, DL
Vander Heyden, Y
机构
[1] Vrije Univ Brussels, Inst Pharmaceut, Dept Pharmaceut & Biomed Anat, Chemo AC, B-1090 Brussels, Belgium
[2] Johnson & Johnson Pharmaceut Res & Dev, Global Analyt Dev, B-2340 Beerse, Belgium
[3] Johnson & Johnson Pharmaceut Res & Dev, Drug Evaluat Analyt Chem, B-2340 Beerse, Belgium
关键词
orthogonal chromatographic systems; correlation coefficients color map; weighted-average-linkage dendrogram; Derringer's desirability function; method development;
D O I
10.1016/j.chroma.2005.03.085
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The starting point of this study was a current set of 32 chromatographic systems used to select initial conditions for method development to determine the impurity profile of a drug. The system exhibiting the best selectivity is then selected for further method development. In this current set eight silica-based phases are applied in conjunction with four mobile phases at different pH. In order to save time and resources, the possibilities for a meaningful subset selection were investigated. The most differing systems in terms of selectivity, in other words only the most orthogonal systems, need to be selected. Since the stationary phases are all silica-based, the selectivity differences are examined within a more homogeneous group than if, for instance, also zirconia- or polymer-based columns would be involved. To select the subset of systems also the best overall separation performances are taken into account. The selection is based both on the HPLC-DAD data of a generic set of 68 drugs, and on the LC-MS-DAD results for a mixture of 15 drugs, less different in structure. The orthogonality is evaluated using weighted-average-linkage dendrograms and color maps, both created from the Pearson-correlation coefficients tau between normalized retention times tau. The Derringer's desirability functions are applied to define the systems with the best overall separation performances. Proposals for different representative subsets of the initial 32 systems are made. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:117 / 131
页数:15
相关论文
共 24 条
[1]  
[Anonymous], 1983, INTERPRETATION ANAL
[2]  
1998, HDB CHEMOMETRICS QUA, V11, P310
[3]   SIMULTANEOUS-OPTIMIZATION OF SEVERAL CHROMATOGRAPHIC PERFORMANCE GOALS USING DERRINGER DESIRABILITY FUNCTION [J].
BOURGUIGNON, B ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (01) :11-20
[4]   Representative subset selection [J].
Daszykowski, M ;
Walczak, B ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 2002, 468 (01) :91-103
[5]   Looking for natural patterns in analytical data. 2. Tracing local density with OPTICS [J].
Daszykowski, M ;
Walczak, B ;
Massart, DL .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2002, 42 (03) :500-507
[6]  
DERRINGER G, 1980, J QUAL TECHNOL, V12, P214, DOI 10.1080/00224065.1980.11980968
[7]  
DERRINGER GC, 1994, QUALITY PROGR JUN, P51
[8]  
*EUR AG EV MED PRO, 2002, ICH TOP Q3A
[9]  
Harrington E. C., 1965, IND QUALITY CONTROL, V21, P494, DOI DOI 10.1128/AM.13.3.494-495.1965
[10]   Application of Derringer's desirability function for the selection of optimum separation conditions in capillary zone electrophoresis [J].
Jimidar, M ;
Bourguignon, B ;
Massart, DL .
JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (01) :109-117