Characterization of blood flow turbulence with pulsed-wave and power Doppler ultrasound imaging

被引:23
作者
Cloutier, G
Allard, L
Durand, LG
机构
[1] Laboratoire de Génie Biomédical, Institut de Recherches Cliniques de Montréal, Montréal, QC, H2W 1R7
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 1996年 / 118卷 / 03期
关键词
D O I
10.1115/1.2796013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood flow turbulence downstream of a concentric 86 percent area reduction stenosis was characterized using absolute and relative Doppler spectral broadening measurements, relative Doppler velocity fluctuation and Doppler backscattered power. Bidimensional mappings of each Doppler inner were obtained using a 10 MHz pulsed-wave Doppler system. Calf red cells suspended in a saline solution were used to scatter ultrasound and were circulated in an in vitro steady flow loop model. Results showed that the absolute spectral broadening was not a good index of turbulence because it was strongly affected by the deceleration of the jet and by the shear layer between the jet and the recirculation zones. Relative Doppler spectral broadening (absolute broadening divided by the frequency shift), velocity fluctuation, and Doppler power indices provided consistent mapping of the centerline axial variation of turbulence evaluated by hot-film anemometry. The best agreement between the hot-film and Doppler ultrasound methods was however obtained with the Doppler backscattered power. The most consistent bidimensional mapping of the flow characteristics downstream of the stenosis was also observed with the Doppler power index. The relative broadening and the velocity fluctuation produced artifacts in the shear layer and in the recirculation zones. Power Doppler imaging is a new emerging technique that may provide reliable in vivo characterization of blood flow turbulence.
引用
收藏
页码:318 / 325
页数:8
相关论文
共 34 条
[1]   FLOW DISTURBANCE MEASUREMENTS THROUGH A CONSTRICTED TUBE AT MODERATE REYNOLDS-NUMBERS [J].
AHMED, SA ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1983, 16 (12) :955-963
[2]   ON THE DOPPLER SIGNAL FROM A STEADY FLOW ASYMMETRICAL STENOSIS MODEL - EFFECTS OF TURBULENCE [J].
BASCOM, PAJ ;
COBBOLD, RSC ;
ROUTH, HF ;
JOHNSTON, KW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (03) :197-210
[3]  
BASCOM PAJ, 1988, ULTRASONICS S, V2, P985
[4]   DISORDER DISTAL TO MODELED STENOSES IN STEADY AND PULSATILE FLOW [J].
CASSANOVA, RA ;
GIDDENS, DP .
JOURNAL OF BIOMECHANICS, 1978, 11 (10-1) :441-453
[5]   25 + 1 CHANNEL PULSED ULTRASOUND DOPPLER VELOCITY METER FOR QUANTITATIVE FLOW MEASUREMENTS AND TURBULENCE ANALYSIS [J].
CASTY, M ;
GIDDENS, DP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1984, 10 (02) :161-172
[6]  
CHAHED N, 1991, BIORHEOLOGY, V28, P383
[7]  
Christensen D., 1988, ULTRASONIC BIOINSTRU
[8]   CYCLIC VARIATION OF THE POWER OF ULTRASONIC DOPPLER SIGNALS BACKSCATTERED BY POLYSTYRENE MICROSPHERES AND PORCINE ERYTHROCYTE SUSPENSIONS [J].
CLOUTIER, G ;
SHUNG, KK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (09) :953-962
[9]   CHANGES IN ULTRASONIC DOPPLER BACKSCATTERED POWER DOWNSTREAM OF CONCENTRIC AND ECCENTRIC STENOSES UNDER PULSATILE FLOW [J].
CLOUTIER, G ;
ALLARD, L ;
DURAND, LG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (01) :59-70
[10]   EXPERIMENTAL EVALUATION OF INTRINSIC AND NONSTATIONARY ULTRASONIC DOPPLER SPECTRAL BROADENING IN STEADY AND PULSATILE FLOW LOOP MODELS [J].
CLOUTIER, G ;
SHUNG, KK ;
DURAND, LG .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (06) :786-795