Mechanical properties of the human uterine cervix: An in vivo study

被引:75
作者
Mazza, E [1 ]
Nava, A
Bauer, M
Winter, R
Bajka, M
Holzapfel, GA
机构
[1] Swiss Fed Inst Technol, Dept Mech Engn, CH-8092 Zurich, Switzerland
[2] Med Univ Graz, Dept Obstet & Gynecol, A-8036 Graz, Austria
[3] Univ Zurich Hosp, Dept Obstet & Gynecol, CH-8091 Zurich, Switzerland
[4] Royal Inst Technol, Dept Solid Mech, S-10044 Stockholm, Sweden
[5] Graz Univ Technol, Inst Struct Anal Computat Biomech, A-8010 Graz, Austria
关键词
uterine cervix; preterm delivery; in vivo experiment; aspiration device; image analysis; constitutive modelling; mechanical properties;
D O I
10.1016/j.media.2005.06.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Experimental results of in vivo measurements to characterize the mechanical behaviour of human uterine cervices are documented. Aspiration experiments were performed on eight uteri in vivo, before vaginal/abdominal hysterectomy, and four uteri were also tested ex vivo, approximately 1.5 h after extraction. The reproducibility of the mechanical data from the in vivo aspiration experiments has been analysed. For an introduced "stiffness parameter" the organ specific SD is 22%, so that the proposed experimental procedure allows detections of 30% changes with respect to a reference value of the stiffness parameter, A comparison of in vivo and ex vivo data from the same organ has shown that: (i) the ex vivo mechanical response of the uterine cervix tissue does not differ considerably from that observed in vivo; (ii) some differences can be identified in tissue pre-conditioning with ex vivo showing a stronger history dependence with respect to in vivo; (iii) the differences in the time dependence of the mechanical response are not significant and might be masked by the variability of the measured data. This study represents a first step of a clinical application aiming at analysing the mechanical response of normal cervical tissue at different gestational ages, and identifying the mechanical properties that characterize pathologic conditions such as cervical insufficiency leading to preterm delivery. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 31 条
[21]   Biomechanics series: Part 2 - TeMPeST I-D: An instrument for measuring solid organ soft tissue properties [J].
Ottensmeyer, M .
EXPERIMENTAL TECHNIQUES, 2002, 26 (03) :48-50
[22]   Improving realism of a surgery simulator: linear anisotropic elasticity, complex interactions and force extrapolation [J].
Picinbono, G ;
Lombardo, JC ;
Delingette, H ;
Ayache, N .
JOURNAL OF VISUALIZATION AND COMPUTER ANIMATION, 2002, 13 (03) :147-167
[23]  
RECHBERGER T, 1988, OBSTET GYNECOL, V71, P563
[24]   Strain-rate dependent material properties of the porcine and human kidney capsule [J].
Snedeker, JG ;
Niederer, P ;
Schmidlin, FR ;
Farshad, M ;
Demetropoulos, CK ;
Lee, JB ;
Yang, KH .
JOURNAL OF BIOMECHANICS, 2005, 38 (05) :1011-1021
[25]   The creation of a high-fidelity finite element model of the kidney for use in trauma research [J].
Snedeker, JG ;
Bajka, M ;
Hug, JM ;
Székely, G ;
Niederer, P .
JOURNAL OF VISUALIZATION AND COMPUTER ANIMATION, 2002, 13 (01) :53-64
[26]   Surgical simulators [J].
Székely, G .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2003, 12 (1-2) :14-18
[27]   Virtual reality-based simulation of endoscopic surgery [J].
Székely, G ;
Brechbühler, C ;
Dual, J ;
Enzler, R ;
Hug, J ;
Hutter, R ;
Ironmonger, N ;
Kauer, M ;
Meier, V ;
Niederer, P ;
Rhomberg, A ;
Schmid, P ;
Schweitzer, G ;
Thaler, M ;
Vuskovic, V ;
Tröster, G ;
Haller, U ;
Bajka, M .
PRESENCE-VIRTUAL AND AUGMENTED REALITY, 2000, 9 (03) :310-333
[28]   SINGLE TRANSVAGINAL SONOGRAPHIC MEASUREMENT OF CERVICAL LENGTH EARLY IN THE 3RD TRIMESTER AS A PREDICTOR OF PRETERM DELIVERY [J].
TONGSONG, T ;
KAMPRAPANTH, P ;
SRISOMBOON, J ;
WANAPIRAK, C ;
PIYAMONGKOL, W ;
SIRICHOTIYAKUL, S .
OBSTETRICS AND GYNECOLOGY, 1995, 86 (02) :184-187
[29]   Nonlinear viscoelastic material property estimation of lower extremity residual limb tissues [J].
Tönük, E ;
Silver-Thorn, MB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (02) :289-300
[30]  
Vuskovic V, 2001, THESIS