A new technique for lag screw placement in the dynamic hip screw fixation of intertrochanteric fractures: decreasing radiation time dramatically

被引:13
作者
Sheng, Wei-Chao [1 ]
Li, Jia-Zhen [2 ]
Chen, Sheng-Hua [1 ]
Zhong, Shi-Zhen [1 ]
机构
[1] So Med Univ, Dept Anat, Guangzhou 510515, Guangdong, Peoples R China
[2] Zhengzhou Univ, Dept Orthopaed, Affiliated Hosp 1, Zhengzhou 450052, Peoples R China
关键词
SLIDING SCREW; GAMMA-NAIL; FAILURE;
D O I
10.1007/s00264-008-0517-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The goal of this study was to confirm the decrease in radiation time required for a new technique to place dynamic hip screws (DHS) in intertrochanteric fractures. Seventy-six patients were treated with DHS by either the new technique (NT) or the conventional technique (CT). The width of femoral shaft, the length of the hip screw to be implanted into the injured side, and the distance between the tip of the greater trochanter and the entry point of the guide wire were measured at the uninjured side on the anteroposterior pelvic radiograph preoperatively, and the actual width of the injured femoral shaft was measured intra-operatively. Finally, the entry point and the length of hip screw were obtained through an equation. Mean radiation time of the NT patients (24.57 +/- 7.80 s) was significantly shorter than the CT patients (54.2 +/- 18.26 s) (P < 0.001). The new technique decreased radiation time dramatically in DHS fixation.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 22 条
[1]
Adams JC, 1992, STANDARD ORTHOPAEDIC, P260
[2]
Minimally invasive dynamic hip screw - Prospective Randomized trial of two techniques of insertion of a standard dynamic fixation device [J].
Alobaid, A ;
Harvey, EJ ;
Elder, GM ;
Lander, P ;
Guy, P ;
Reindl, R .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (04) :207-212
[3]
[Anonymous], CAMPBELLS OPERATIVE
[4]
SLIPPED CAPITAL FEMORAL EPIPHYSIS - A PROSPECTIVE-STUDY OF FIXATION WITH A SINGLE SCREW [J].
ARONSON, DD ;
CARLSON, WE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :810-819
[5]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[6]
Robotic-assisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique [J].
Browbank, I ;
Bouazza-Marouf, K ;
Schnabler, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H2) :165-179
[7]
INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[8]
DELEE JC, 1991, ROCKWOOD GREENS FRAC, P1481
[9]
Potential of P40 plastination for morphometric hip measurements [J].
Genser-Strobl, B ;
Sora, MC .
SURGICAL AND RADIOLOGIC ANATOMY, 2005, 27 (02) :147-151
[10]
HAYDAR AJ, 2005, EUR J ORTHOP SURG TR, V15, P11