Evaluation of different internal-diameter column combinations in comprehensive two-dimensional gas chromatography in flavour and fragrance analysis

被引:19
作者
Cordero, Chiara [1 ]
Bicchi, Carlo [1 ]
Galli, Mario [2 ]
Galli, Stefano [2 ]
Rubiolo, Patrizia [1 ]
机构
[1] Univ Turin, Dipartimento Sci & Tecnol Farmaco, I-10125 Turin, Italy
[2] MEGA, Milan, Italy
关键词
Column diameter combinations; Fingerprint analysis; GC x GC Separation efficiency; Target analysis;
D O I
10.1002/jssc.200800280
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A series of OV1-OV1701 column sets, in which the two dimensions differ in id and/or film thickness, were adopted to separate components of the volatile and semivolatile fraction of samples of plant origin. In particular two applications are presented: a target analysis approach to determine volatile suspected allergens in a medium-complexity fragrance and in sandalwood essential oil, and a fingerprint analysis approach to compare herbal extracts. Some basic chromatographic parameters of these combinations, i.e. net separation measure (S-GC (x) (GC)), degree of orthogonality and a suitable number of modulations per peak, were also estimated by analysing two test mixtures: FAME (C4:0-C24:0) and suspected volatile allergens. Experimental results show that 0.25 mm homologous id column combination, despite their lower separation power, have good capacity to separate and resolve medium-to-complex fractions from samples of plant origin, demonstrating: (i) good system orthogonality, maximized through proper exploitation of stationary-phase selectivity and (ii) reduced 2-D column overloading effects due to the increased 2-D mass loadability, thus facilitating the analysis of mixtures whose components differ significantly in relative abundance.
引用
收藏
页码:3437 / 3450
页数:14
相关论文
共 39 条
[1]
Recent developments in the application of comprehensive two-dimensional gas chromatography [J].
Adahchour, M. ;
Beens, J. ;
Brinkman, U. A. Th. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) :67-108
[2]
Recent developments in comprehensive two-dimensional gas chromatography (GC x GC) III. Applications for petrochemicals and organohalogens [J].
Adahchour, M. ;
Beens, J. ;
Vreuls, R. J. J. ;
Brinkman, U. A. Th. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :726-741
[3]
Quantification in comprehensive two-dimensional gas chromatography and a model of quantification based on selected summed modulated peaks [J].
Amador-Munoz, Omar ;
Marriott, Philip J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :323-340
[4]
[Anonymous], INN PART IMPR HEALTH
[5]
Flow regime at ambient outlet pressure and its influence in comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Janssen, HG ;
Adahchour, M ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :141-150
[6]
Comprehensive two-dimensional gas chromatography: metrics, potentials, limits [J].
Blumberg, LM .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :29-38
[7]
Metrics of separation in chromatography [J].
Blumberg, LM ;
Klee, MS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 933 (1-2) :1-11
[8]
*COMM PROPR MED PR, 1996, INT C HARMM ICH COMM
[9]
CORDERO C, 2008, J AGR FOOD IN PRESS
[10]
CORDERO C, 2008, 5 GC GC S JUN 26 28