In this work we present a novel scheme for performing infrared multiphoton dissociation (IRMPD) external to the mass analyzer in an external ion reservoir consisting of an rf-only multipole and a pair of electrostatic lens elements. Ions generated by electrospray ionization (ESI) are accumulated in an rf-only hexapole and dissociated by irradiation at 10.6 mu m from a CW CO2 laser in the source region of the mass spectrometer. This scheme is unique from other IRMPD schemes as dissociation occurs in a spatially distinct region of the spectrometer and is independent of the mass spectrometry platform used to analyze the fragment ions. The effectiveness of the technique is demonstrated with ESI IRMPD FTICR mass spectrometry of a 20-mer phosphorothioate oligonucleotide. A comparison of the external IRMPD scheme with nozzle-skimmer dissociation and conventional in-cell IRMPD reveals a significant improvement in signal-to-noise ratio and fragment yield, particularly for larger, more highly charged fragment ions.
引用
收藏
页码:2067 / 2070
页数:4
相关论文
共 19 条
[1]   INFRARED MULTIPHOTON DISSOCIATION OF SOME OXYGEN-CONTAINING HYDROCARBON IONS - DIFFERENTIATION OF ISOMERIC ION STRUCTURES IN THE GAS-PHASE [J].
BAYKUT, G ;
WATSON, CH ;
WELLER, RR ;
EYLER, JR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1985, 107 (26) :8036-8042
[2]   ENERGETICS OF THE REARRANGEMENT OF NEUTRAL AND IONIZED PERFLUOROCYCLOPROPANE TO PERFLUOROPROPYLENE - USE OF INFRARED MULTI-PHOTON DISSOCIATION SPECTRA TO IDENTIFY STRUCTURAL ISOMERS OF MOLECULAR-IONS [J].
BOMSE, DS ;
BERMAN, DW ;
BEAUCHAMP, JL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1981, 103 (14) :3967-3971
[3]  
Campbell JM, 1998, RAPID COMMUN MASS SP, V12, P1463, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1463::AID-RCM357>3.3.CO
[4]  
2-8
[5]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518
[6]   Use of infrared multiphoton photodissociation with SWIFT for electrospray ionization and laser desorption applications in a quadrupole ion trap mass spectrometer [J].
Colorado, A ;
Shen, JXX ;
Vartanian, VH ;
Brodbelt, J .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :4033-4043
[7]   ION-CYCLOTRON RESONANCE TIME-OF-FLIGHT SPECTROSCOPY - KINETIC-ENERGY OF PARA-IODOTOLUENE PHOTODISSOCIATION FRAGMENT IONS [J].
DUNBAR, RC ;
WEDDLE, GH .
JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (20) :5706-5709
[8]  
Hofstadler SA, 1998, RAPID COMMUN MASS SP, V12, P1400, DOI 10.1002/(SICI)1097-0231(19981015)12:19<1400::AID-RCM337>3.0.CO
[9]  
2-T
[10]  
HUGHES RJ, 1983, CAN J CHEM, V61, P834