Descending thoracic aortic aneurysm: Thoracic CT findings after endovascular stent-graft placement

被引:33
作者
Sakai, T
Dake, MD
Semba, CP
Yamada, T
Arakawa, A
Kee, ST
Hayashi, N
Razavi, MK
Sze, DY
机构
[1] Stanford Univ, Med Ctr, Dept Cardiovasc & Intervent Radiol, Stanford, CA 94305 USA
[2] Fukui Med Univ, Sch Med, Dept Radiol, Fukui, Japan
关键词
aneurysm; aortic; aorta; grafts and prostheses; interventional procedures;
D O I
10.1148/radiology.212.1.r99jl37169
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the usefulness of thoracic computed tomography (CT) after placement of an endovascular stent-graft for the treatment of descending thoracic aortic aneurysm. MATERIALS AND METHODS: From 1992 to 1996, 85 patients with thoracic aortic aneurysm underwent stent-graft placement. In 63 patients, thoracic CT scans were obtained both before and within 10 days after placement. The CT findings were retrospectively studied, and their clinical effect analyzed. In 20 of 63 patients, long-term follow-up CT findings were also evaluated. RESULTS: After stent-graft placement in the 63 patients, CT demonstrated an increase in pleural effusion in 46 (73%), periaortic changes in 21 and (33%), perigraft leak in 13 (21%), atelectasis in six (10%), mural thrombus within the stent-graft in two (3%), and new aortic dissection in one (2%). The mean maximum diameter of the aneurysm was 58.9 mm before and 60.0 mm after stent-graft insertion. Sixty-two (98%) patients were successfully treated until discharge. Interventional procedures were performed to eliminate the leakage into the aneurysm sac in 10 patients with perigraft flow depicted at CT. Other complications were managed conservatively. CONCLUSION: Thoracic CT is useful in the treatment of patients after stent-graft insertion for the management of descending thoracic aortic aneurysm.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 25 条
[1]   Abdominal aortic aneurysms: Preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts [J].
Blum, U ;
Langer, M ;
Spillner, G ;
Mialhe, C ;
Beyersdorf, F ;
BuitragoTellez, C ;
Voshage, G ;
Duber, C ;
Schlosser, V ;
Cragg, AH .
RADIOLOGY, 1996, 198 (01) :25-31
[2]   PULMONARY DENSITIES DURING ANESTHESIA WITH MUSCULAR RELAXATION - A PROPOSAL OF ATELECTASIS [J].
BRISMAR, B ;
HEDENSTIERNA, G ;
LUNDQUIST, H ;
STRANDBERG, A ;
SVENSSON, L ;
TOKICS, L .
ANESTHESIOLOGY, 1985, 62 (04) :422-428
[3]   Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair [J].
Chuter, TAM ;
Risberg, B ;
Hopkinson, BR ;
Wendt, G ;
Scott, RAP ;
Walker, PJ ;
Viscomi, S ;
White, G .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) :655-666
[4]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[5]   ENDOVASCULAR STENT-GRAFTING AFTER ARCH ANEURYSM REPAIR USING THE ELEPHANT TRUNK [J].
FANN, JI ;
DAKE, MD ;
SEMBA, CP ;
LIDDELL, RP ;
PFEFFER, TA ;
MILLER, DC .
ANNALS OF THORACIC SURGERY, 1995, 60 (04) :1102-1105
[6]   Traumatic thoracic aortic aneurysm: Treatment with endovascular stent-grafts [J].
Kato, N ;
Dake, MD ;
Miller, DC ;
Semba, CP ;
Mitchell, RS ;
Razavi, MK ;
Kee, ST .
RADIOLOGY, 1997, 205 (03) :657-662
[7]   Embolization of perigraft leaks after endovascular stent-graft treatment of aortic aneurysms [J].
Kato, N ;
Semba, CP ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (06) :805-811
[8]   MR imaging of soft-tissue changes after percutaneous transluminal angioplasty and stent placement [J].
Kellner, W ;
Kuffer, G ;
Pfluger, T ;
Rosa, FT ;
Hahn, K .
RADIOLOGY, 1997, 202 (02) :327-331
[9]  
Link J, 1996, CARDIOVASC INTER RAD, V19, P345
[10]   Dacron-covered stent-grafts for the percutaneous treatment of carotid aneurysms: Effectiveness and biocompatibility - Experimental study in swine [J].
Link, J ;
Feyerabend, B ;
Grabener, M ;
Linstedt, U ;
Brossmann, J ;
Thomsen, H ;
Heller, M .
RADIOLOGY, 1996, 200 (02) :397-401