Effects of multisite ventricular pacing on cardiac function in normal dogs and dogs with heart failure

被引:20
作者
Fei, L
Wrobleski, D
Groh, W
Vetter, A
Duffin, EG
Zipes, DP
机构
[1] Indiana Univ, Sch Med, Krannert Inst Cardiol, Dept Med, Indianapolis, IN 46202 USA
[2] Richard L Roudebush Vet Adm Med Ctr, Indianapolis, IN USA
[3] Medtron Inc, Minneapolis, MN USA
关键词
cardiac output; contractility; heart failure; hemodynamics; pacing;
D O I
10.1111/j.1540-8167.1999.tb01264.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: We studied the effects on cardiac function of pacing two right and two left ventricular sites in normal and failing hearts with a normal QRS duration. Methods and Results: Hemodynamic parameters were studied in isoflurane-anesthetized dogs with normal hearts and dogs with heart failure induced by rapid ventricular pacing, Unipolar intramyocardial electrodes were placed at the high right atrium and the apex (A) and base (B) of the left(L) and right (R) ventricles (V), Data were collected after pacing for 5 to 20 minutes, In normal dogs, without bundle branch block (BBB), pacing at either the apex or the base of the left ventricle increased cardiac output by approximately 10% compared with right ventricular apex (RVA) pacing with an AV delay of 0 msec, Positive dP/dt increased approximately 10% during four-site left and right ventricular apex and base (LRVAB) pacing compared with RVA pacing, In dogs with heart failure but without BBB, cardiac output increased by 8.5% (P < 0.01) during four-site ventricular pacing with AV delays of 0 and 60 msec compared with PVA pacing. Positive dp/dt increased by 23.5% (P < 0.001) with an AV delay of 0 msec and 9.6% (P < 0.001) with an AV delay of 60 msec during LRVAB pacing compared with RVA pacing. His-bundle pacing was associated with increased cardiac output compared with RVA pacing, Conclusions: We conclude that pacing simultaneously at two right and two left ventricular sites significantly improves cardiac function compared with single PVA pacing, with or without sequential AV synchrony, in dogs with rapid ventricular pacing-induced heart failure and no BBB.
引用
收藏
页码:935 / 946
页数:12
相关论文
共 44 条
  • [11] EFFECTS OF DUAL-CHAMBER PACING WITH SHORT ATRIOVENTRICULAR DELAY IN DILATED CARDIOMYOPATHY
    BRECKER, SJD
    XIAO, HB
    SPARROW, J
    GIBSON, DG
    [J]. LANCET, 1992, 340 (8831) : 1308 - 1312
  • [12] PACEMAKER HEMODYNAMICS - CLINICAL IMPLICATIONS
    BUCKINGHAM, TA
    JANOSIK, DL
    PEARSON, AC
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1992, 34 (05) : 347 - 366
  • [13] Acute hemodynamic effects of atrioventricular pacing at differing sites in the right ventricle individually and simultaneously
    Buckingham, TA
    Candinas, R
    Schlapfer, J
    Aebischer, N
    Jeanrenaud, X
    Landolt, J
    Kappenberger, L
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (04): : 909 - 915
  • [14] Chronotropic incompetence .2. Clinical implications
    Camm, AJ
    Fei, L
    [J]. CLINICAL CARDIOLOGY, 1996, 19 (06) : 503 - 508
  • [15] 4-CHAMBER PACING IN DILATED CARDIOMYOPATHY
    CAZEAU, S
    RITTER, P
    BAKDACH, S
    LAZARUS, A
    LIMOUSIN, M
    HENAO, L
    MUNDLER, O
    DAUBERT, JC
    MUGICA, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1974 - 1979
  • [16] Multisite pacing for end-stage heart failure: Early experience
    Cazeau, S
    Ritter, P
    Lazarus, A
    Gras, D
    Backdach, H
    Mundler, O
    Mugica, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1748 - 1757
  • [17] CAZEAU S, 1997, J AM COLL CARDIOL, V29, p111A
  • [18] SEPTAL SHORT ATRIOVENTRICULAR DELAY PACING - ADDITIONAL HEMODYNAMIC IMPROVEMENTS IN HEART-FAILURE
    COWELL, R
    MORRISTHURGOOD, J
    ILSLEY, C
    PAUL, V
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1980 - 1983
  • [19] EINSTEIN R, 1995, CLIN EXP PHARMACOL P, V22, P864, DOI 10.1111/j.1440-1681.1995.tb01952.x
  • [20] Fei L, 1996, EUR HEART J, V17, P258