Intraoperative probes and imaging probes

被引:67
作者
Hoffman, EJ
Tornai, MP
Janecek, R
Patt, BE
Iwanczyk, JS
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Pharmacol, Div Nucl Med, Los Angeles, CA 90095 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[3] Photon Imaging Inc, Northridge, CA USA
关键词
intraoperative probes; sentinel node detection;
D O I
10.1007/s002590050468
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intraoperative probes have been employed to assist in the detection and removal of tumors for more than 50 years, For a period of about 40 years, essentially every detector type that could be miniaturized had been tested or at least suggested for use as an intraoperative probe. These detectors included basic Geiger-Muller (GM) tubes, scintillation detectors, and even state-of-the - art solid state detectors. The radiopharmaceuticals have progressed from (PO4)-P-32- injections for brain tumors to sophisticated monoclonal antibodies labeled with iodine-125 for colorectal cancers. The early work was mostly anecdotal, primarily interdisciplinary collaborations between surgeons and physical scientists. These collaborations produced a few publications, but never seemed to result in an ongoing clinical practice. In the mid 1980s, several companies offered basic gamma-detecting intraoperative probes as products. This led to the rapid development of radioimmunoguided surgery (RIGS) and sentinel node detection as regularly practiced procedures to assist in the diagnosis and treatment of cancer. In recent years intraoperative imaging probes have been developed. These devices add the ability to see the details of the detected activity, giving the potential of using the technique in a low-contrast environment. Intraoperative probes are now established as clinical devices, they have a commercial infrastructure to support their continued use, and there is ongoing research, both commercial and academic, that would seem to ensure continued progress and renewed interest in this slowly developing field.
引用
收藏
页码:913 / 935
页数:23
相关论文
共 169 条
[41]   INTRAOPERATIVE BETA-PROBE - A DEVICE FOR DETECTING TISSUE LABELED WITH POSITRON OR ELECTRON EMITTING ISOTOPES DURING SURGERY [J].
DAGHIGHIAN, F ;
MAZZIOTTA, JC ;
HOFFMAN, EJ ;
SHENDEROV, P ;
ESHAGHIAN, B ;
SIEGEL, S ;
PHELPS, ME .
MEDICAL PHYSICS, 1994, 21 (01) :153-157
[42]  
de Hullu JA, 1998, J NUCL MED, V39, P1381
[43]   Combination of monoclonal antibodies for radioimmunoguided surgery [J].
deNardi, P ;
Stella, M ;
Magnani, P ;
Paganelli, G ;
Mangili, F ;
Fazio, F ;
diCarlo, V .
INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 1997, 12 (01) :24-28
[44]  
Di Carlo V, 1998, SEMIN SURG ONCOL, V15, P235, DOI 10.1002/(SICI)1098-2388(199812)15:4<235::AID-SSU10>3.0.CO
[45]  
2-B
[46]  
DICARLO V, 1995, TUMORI, V81, P98
[47]  
Dresel S, 1998, NUKLEARMED, V37, P177
[48]   Reactor-produced radionuclides at the University of Missouri Research Reactor [J].
Ehrhardt, GJ ;
Ketring, AR ;
Ayers, LM .
APPLIED RADIATION AND ISOTOPES, 1998, 49 (04) :295-297
[49]   LYMPHATIC MAPPING AND SENTINEL LYMPHADENECTOMY FOR BREAST-CANCER [J].
GIULIANO, AE ;
KIRGAN, DM ;
GUENTHER, JM ;
MORTON, DL .
ANNALS OF SURGERY, 1994, 220 (03) :391-401
[50]   The use of intraoperative radiolymphoscintigraphy for sentinel node biopsy in patients with malignant melanoma [J].
Glass, LF ;
Messina, JL ;
Cruse, W ;
Wells, K ;
Rapaport, D ;
Miliotes, G ;
Berman, C ;
Reintgen, D ;
Fenske, NA .
DERMATOLOGIC SURGERY, 1996, 22 (08) :715-720