The ETV as a thermochemical reactor for ICP-MS sample introduction

被引:70
作者
Sturgeon, RE [1 ]
Lam, JW [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R9, Canada
关键词
D O I
10.1039/a809460h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrothermal vaporization (Em) for sample introduction into (inductively coupled) plasmas has been explored for more than two decades, first for use with optical spectroscopy and subsequently with mass spectrometry. It is with the latter that its full potential has been appreciated vis-a-vis solution sample nebulization. Tandem coupling of an ETV to a plasma source elicits a number of attractive features, not least of which is the explicit use of the device as a thermochemical reactor for in situ pretreatment of samples. This aspect of ETV use has not yet been sufficiently well explored, despite an accumulated body of literature in the related field of ETAAS, where judicious selection of thermal programs and chemical modifiers has been extensively used to minimize analytical problems. Of particular interest for ETV sample introduction is the feasibility of using classical chemical modifiers or other reagents to alter the volatility of either the analyte or the concomitant matrix, thereby permitting a thermal or temporal separation of their release from the ETV surface. This approach may alleviate space charge interference effects, minimize polyatomic ion interferences and effectively enhance resolution, permit direct speciation of trace element fractions in samples as well as serve as a 'crucible' for sample preparation. The literature in this field is reviewed and examples of such applications for ICP-AES and ICP-MS detection are presented.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 82 条
[31]   APPLICATION OF EDTA TO DIRECT GRAPHITE-FURNACE ATOMIC-ABSORPTION ANALYSIS FOR CADMIUM IN SEA-WATER [J].
GUEVREMONT, R ;
STURGEON, RE ;
BERMAN, SS .
ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) :163-170
[33]  
Horlick G, 1998, INDUCTIVELY COUPLED PLASMAS MASS SPECTROMETRY, P503
[34]   Determination of trace impurities in high-purity tungsten by direct solid sampling electrothermal atomic absorption spectrometry using a transversely heated graphite tube [J].
Hornung, M ;
Krivan, V .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3444-3451
[35]   FLUORINATION AND VOLATILIZATION OF REFRACTORY ELEMENTS FROM A GRAPHITE-FURNACE FOR SAMPLE INTRODUCTION INTO AN INDUCTIVELY COUPLED PLASMA BY USING A POLYTETRAFLUOROETHYLENE SLURRY [J].
HUANG, M ;
JIANG, ZC ;
ZENG, Y .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) :221-224
[36]   INTERPRETING SOME ANALYTICAL CHARACTERISTICS OF THERMAL DISPERSION METHODS USED FOR SAMPLE INTRODUCTION IN ATOMIC SPECTROMETRY [J].
KANTOR, T .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (9-11) :1299-1320
[37]  
Kantor T, 1996, FRESEN J ANAL CHEM, V355, P606
[38]  
KARANASSIOS V, 1990, SPECTROCHIM ACTA REV, V13, P89
[39]   ELIMINATION OF SOME SPECTRAL INTERFERENCES AND MATRIX EFFECTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING DIRECT SAMPLE INSERTION TECHNIQUES [J].
KARANASSIOS, V ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (12) :1387-1396
[40]   ELECTROTHERMAL VAPORIZATION OF TRACE GALLIUM VIA IN-SITU ALKYLATION FOR INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
KUMAMARU, T ;
TAO, SQ ;
UCHIDA, M ;
OKAMOTO, Y .
ANALYTICAL LETTERS, 1994, 27 (12) :2331-2339