A method based on isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has been developed for high-accuracy determinations of mercury in bituminous and sub-bituminous coals. A closed-system digestion process employing a Carius tube is used to completely oxidize the coal matrix and chemically equilibrate the mercury in the sample with a Hg-201 isotopic spike. The digestates are diluted with high-purity quartz-distilled water, and the mercury is released as a vapor by reduction with tin(H) chloride. Measurements of Hg-201/Hg-202 isotope ratios are made using a quadrupole ICPMS system in time-resolved analysis mode. The new method has some significant advantages over e existing methods. The instrument detection limit is less than 1 pg/mL. The average blank (n = 17) is 30 pg, which is roughly 1 order of magnitude lower than the equivalent microwave digestion procedure. The detection limit in coal is blank limited and is similar to40 pg/g. Memory effects are very low. The relative reproducibility of the analytical measurements is similar to0.5% for mercury concentrations in the range 10-150 ng/g. The method has been used to measure mercury concentrations in six coal reference materials, SRM 1632b (77.4 ng/g), SRM 1632c (94.3 ng/g), BCR 40 (433.2 ng/g), BCR 180 (125.0 ng/g), BCR 181 (135.8 ng/g), and SARM 20 (252.6 ng/g), as well as a coal fly ash, SRM 1633b (143.1 ng/g). The method is equally applicable to other types of fossil fuels including both crude and refined oils.
引用
收藏
页码:1477 / 1483
页数:7
相关论文
共 40 条
[1]  
[Anonymous], 1997, MERCURY STUDY REPORT, V3
[2]  
Bettinelli M, 1999, ATOM SPECTROSC, V20, P13
[3]   Determination of mercury in coal using radiochemical neutron activation analysis [J].
Blanchard, LJ ;
Robertson, JD .
ANALYST, 1997, 122 (11) :1261-1264
[4]   A radiochemical neutron activation analysis method for the determination of total mercury in coal [J].
Blanchard, LJ ;
Robertson, JD .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 235 (1-2) :255-259
[5]   Determination of cadmium, mercury and lead in soil samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Chen, SF ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (10) :1113-1117
[6]   Development of isotope dilution cold vapor inductively coupled plasma mass spectrometry and its application to the certification of mercury in NIST standard reference materials [J].
Christopher, SJ ;
Long, SE ;
Rearick, MS ;
Fassett, JD .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2190-2199
[7]   Trace determination of mercury: A review [J].
Clevenger, WL ;
Smith, BW ;
Winefordner, JD .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1997, 27 (01) :1-26
[8]   ROUTINE DETERMINATION OF MERCURY, ARSENIC AND SELENIUM BY RADIOCHEMICAL NEUTRON-ACTIVATION ANALYSIS [J].
DRABAEK, I ;
CARLSEN, V ;
JUST, L .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1986, 103 (04) :249-260
[9]  
DUMAREY R, 1985, B SOC CHIM BELG, V94, P351
[10]   DETERMINATION OF MERCURY IN COAL BY NON-OXIDATIVE PYROLYSIS AND COLD VAPOR ATOMIC-FLUORESCENCE SPECTROMETRY [J].
EBDON, L ;
WILKINSON, JR ;
JACKSON, KW .
ANALYST, 1982, 107 (1272) :269-275