Development of piezoelectric immunosensors for measurement of albuminuria

被引:29
作者
Navrátilová, I
Skládal, P
Viklicky, V
机构
[1] Masaryk Univ, Fac Sci, Dept Biochem, CZ-61137 Brno, Czech Republic
[2] EXBIO Praha, Prague 14200, Czech Republic
[3] Acad Sci Czech Republ, Inst Mol Genet, Prague 14200, Czech Republic
关键词
immunosensor; quartz crystal microbalance; human serum albumin; albuminuria;
D O I
10.1016/S0039-9140(01)00512-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of piezoelectric immunosensors for human serum albumin (HSA) is reported. The piezoelectric crystals were modified either with monoclonal antibody AL-01 (direct assay) or with HSA (competitive assay). Measurements were carried out in the flow-through mode. Affinity interaction between albumin and the antibody was characterised. With immobilised antibody and HSA in solution, the kinetic association rate constant k(a) was 181001 mol(-1) s(-1) and the dissociation constant k(d) was 0.00369 s(-1). For the opposite arrangement (immobilised HSA), a slower dissociation was observed, k(d) was 0.00085 s(-1). A competitive assay for HSA was developed with working range of 1-5 mug ml(-1) and a total time for one analysis equal to 17 min. Samples of urine were analysed after tenfold dilution. The developed system was successfully evaluated on real samples from diabetic patients and the obtained results correlated well with the standard reflectometric assay of proteins in urine. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:831 / 839
页数:9
相关论文
共 15 条
[1]  
ANGELISOVA P, 1986, FOLIA BIOL-PRAGUE, V32, P289
[2]  
Chu X, 1997, ANAL LETT, V30, P1783
[3]   ALBUMIN STANDARDS AND MEASUREMENT OF SERUM ALBUMIN WITH BROMCRESOL GREEN [J].
DOUMAS, BT ;
WATSON, WA ;
BIGGS, HG .
CLINICA CHIMICA ACTA, 1971, 31 (01) :87-&
[4]   SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS [J].
HAYES, FJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1860-1865
[5]  
HERMANSON GT, 1992, IMMOBILIZED AFFINITY, P69
[6]   Effect of organic solvents on immunoassays of environmental pollutants studied using a piezoelectric biosensor [J].
Horácek, J ;
Skládal, P .
ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) :37-45
[7]   AMPEROMETRIC ENZYME-IMMUNOASSAY FOR URINARY HUMAN SERUM-ALBUMIN USING PLASMA-TREATED MEMBRANE [J].
KAKU, S ;
NAKANISHI, S ;
HORIGUCHI, K ;
SATO, M .
ANALYTICA CHIMICA ACTA, 1993, 272 (02) :213-220
[8]   An on-line quantitative immunoassay system based on a quartz crystal microbalance [J].
Lin, SM ;
Lu, CC ;
Chien, HF ;
Hsu, SM .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 239 (1-2) :121-124
[9]   AFFINITY ELECTRODE - APPLICATION TO THE ASSAY OF HUMAN-SERUM ALBUMIN [J].
LOWE, CR .
FEBS LETTERS, 1979, 106 (02) :405-408
[10]   QUARTZ-CRYSTAL MICROBALANCE FOR THE DETECTION OF MICROGRAM QUANTITIES OF HUMAN SERUM-ALBUMIN - RELATIONSHIP BETWEEN THE FREQUENCY CHANGE AND THE MASS OF PROTEIN ADSORBED [J].
MURATSUGU, M ;
OHTA, F ;
MIYA, Y ;
HOSOKAWA, T ;
KUROSAWA, S ;
KAMO, N ;
IKEDA, H .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2933-2937