Impact of left venticular assist device (LVAD)-mediated humoral sensitization on post-transplant outcomes

被引:70
作者
Joyce, DL
Southard, RE
Torre-Amione, G
Noon, GP
Land, GA
Loebe, M
机构
[1] Baylor Coll Med, Michael E DeBakey Dept Surg, Houston, TX 77030 USA
[2] Baylor Coll Med, Cardiol Sect, Houston, TX 77030 USA
[3] Methodist Hosp, Dept Histocompatibil & Transplant Immunol, Houston, TX 77030 USA
关键词
D O I
10.1016/j.healun.2005.06.028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Humoral sensitization, defined as a panel-reactive antibody (PRA) screen of > 10%, places heart transplant recipients at a greater risk of acute rejection and mortality. Previous studies have suggested an increased sensitization in left ventricular assist device (LVAD) recipients, although neither the impact of device selection nor the clinical importance of elevated PRA in these patients has been completely described. Methods: Using the registry of the International Society for Heart and Lung Transplantation (JSHLT), we compared PRA levels in 7,686 heart transplant recipients to determine the impact of LVAD therapy on humoral sensitization, acute rejection and mortality. To determine the impact of device selection on sensitization, we compared data from the ISHLT registry as well as from our own institution. Results: Elevated PRA levels were found in 16.6% of LVAD recipients, compared with 7.6% of non-LVAD controls (p < 0.0001). Sensitization differed by device type, being present in 21.9% of Thoratec recipients, 14.4% of HeartMate recipients, and 15.5% of Novacor recipients (P = 0.01). Despite these findings, LVAD use had no impact on rejection rates. LVAD use was associated with a small increase (4.4% and 4.3%, respectively) in 1- and 2-year mortality. Conclusions: These findings support the concept that mechanical circulatory support increases the rate of humoral sensitization. However, these differences in sensitization do not translate to substantial differences in the clinical outcomes of rejection and mortality.
引用
收藏
页码:2054 / 2059
页数:6
相关论文
共 20 条
[1]   Panel-reactive antibody screening practices prior to heart transplantation [J].
Betkowski, AS ;
Graff, R ;
Chen, JJ ;
Hauptman, PJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (06) :644-650
[2]   Inhibition of alloresponse by a human trophoblast non-coding RNA suppressing class II transactivator promoter III and major histocompatibility class II expression in murine B-lymphocytes [J].
Geirsson, A ;
Bothwell, AL ;
Hammond, GL .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (09) :1077-1081
[3]   Change in quality of life from after left ventricular assist device implantation to after heart transplantation [J].
Grady, KL ;
Meyer, PM ;
Dressler, D ;
White-Williams, C ;
Kaan, A ;
Mattea, A ;
Ormaza, S ;
Chillcott, S ;
Loo, A ;
Todd, B ;
Costanzo, MR ;
Piccione, W .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2003, 22 (11) :1254-1267
[4]   Change in quality of life from before to after discharge following left ventricular assist device implantation [J].
Grady, KL ;
Meyer, PM ;
Mattea, A ;
Dressler, D ;
Ormaza, S ;
White-Williams, C ;
Chillcott, S ;
Kaan, A ;
Loo, A ;
Todd, B ;
Klemme, A ;
Piccione, W ;
Costanzo, MR .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2003, 22 (03) :322-333
[5]   Preformed IgG antibodies against major histocompatibility complex class II antigens are major risk factors for high-grade cellular rejection in recipients of heart transplantation [J].
Itescu, S ;
Tung, TC ;
Burke, EM ;
Weinberg, A ;
Moazami, N ;
Artrip, JH ;
Suciu-Foca, N ;
Rose, EA ;
Oz, MC ;
Michler, RE .
CIRCULATION, 1998, 98 (08) :786-793
[6]   Intravenous pulse administration of cyclophosphamide is an effective and safe treatment for sensitized cardiac allograft recipients [J].
Itescu, S ;
Burke, E ;
Lietz, K ;
John, R ;
Mancini, D ;
Michler, R ;
Rose, E ;
Oz, M ;
Edwards, N .
CIRCULATION, 2002, 105 (10) :1214-1219
[7]   Immunologic sensitization in recipients of left ventricular assist devices [J].
John, R ;
Lietz, K ;
Schuster, M ;
Naka, J ;
Rao, V ;
Mancini, DM ;
Rose, EA ;
Smith, CR ;
Oz, MC ;
Edwards, NM ;
Itescu, S .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (03) :578-591
[8]  
John R, 1999, CIRCULATION, V100, P229
[9]  
Kobashigawa JA, 1996, CIRCULATION, V94, P294
[10]   HLA sensitization in ventricular assist device recipients: Does type of device make a difference? [J].
Kumpati, GS ;
Cook, DJ ;
Blackstone, EH ;
Rajeswaran, J ;
Abdo, AS ;
Young, JB ;
Starling, RC ;
Smedira, NG ;
McCarthy, PM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06) :1800-1807