Application of ionic liquid-TiO2 nanoparticle modified carbon paste electrode for the voltammetric determination of benserazide in biological samples

被引:97
作者
Ensafi, Ali A. [1 ]
Bahrami, Hajar [1 ]
Rezaei, B. [1 ]
Karimi-Maleh, Hassan [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2013年 / 33卷 / 02期
关键词
Benserazide analysis; Ionic liquid; TiO2; nanoparticles; Carbon paste electrode; Voltammetry; L-DOPA; ELECTROCHEMICAL-BEHAVIOR; SPECTROPHOTOMETRIC DETERMINATION; PHARMACEUTICAL FORMULATIONS; MULTIVARIATE CALIBRATION; LEVODOPA; ACID; NANOTUBES; CHEMILUMINESCENCE; CARBIDOPA;
D O I
10.1016/j.msec.2012.11.008
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
An ionic liquid-TiO2 nanoparticle modified carbon paste electrode (IL-TiO2/CPE) was used as a fast and sensitive tool for the investigation of the electrochemical oxidation of benserazide using voltammetry. This modified electrode has been fabricated using hydrophilic ionic liquid (n-hexyl-3-methylimidazolium hexafluoro phosphate) as a binder. The modified electrode offers a considerable improvement in voltammetric sensitivity toward benserazide, compared to the bare electrode. Using differential pulse voltammetry (DPV), the electrocatalytic oxidation peak current of benserazide shows a linear calibration curve in the range of 1.0-600 mu mol L-1 benserazide. The limit of detection was equal to 0.4 mu mol L-1. The relative standard deviation (RSD%) for eight successive assays of 10 mu mol L-1 benserazide was 1.1%. Finally, the proposed method was successfully applied to the determination of benserazide in real samples such as blood serum and urine. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:831 / 835
页数:5
相关论文
共 38 条
[1]  
[Anonymous], AUSTR DRUG GUIDE
[2]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[3]   Chiral and non chiral determination of Dopa by capillary electrophoresis [J].
Blanco, M ;
Valverde, I .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (03) :431-438
[4]   Electrochemical behavior of catecholamines and related compounds at in situ surfactant modified carbon paste electrodes [J].
Blanco-Lopez, M. Carmen ;
Lobo-Castanon, M. Jesus ;
Ordieres, Arturo J. Miranda ;
Tunon-Blanco, Paulino .
ELECTROANALYSIS, 2007, 19 (2-3) :207-213
[5]   L-DOPA AND PARKINSONISM [J].
CALNE, DB ;
SANDLER, M .
NATURE, 1970, 226 (5240) :21-+
[6]   Simultaneous kinetic-spectrophotometric determination of carbidopa, levodopa and methyldopa in the presence of citrate with the aid of multivariate calibration and artificial neural networks [J].
Chamsaz, M. ;
Safavi, A. ;
Fadaee, J. .
ANALYTICA CHIMICA ACTA, 2007, 603 (02) :140-146
[7]   Simultaneous electrochemical determination of epinephrine and uric acid at 1-butyl-4-methyl-pyridinium tetrafluroborate ionic liquid modified carbon paste electrode: A voltammetric study [J].
Chandrashekar, Bannanakere N. ;
Swamy, Bahaddurghatta E. Kumara ;
Ashoka, Nanjappa B. ;
Pandurangachar, Mundargi .
JOURNAL OF MOLECULAR LIQUIDS, 2012, 165 :168-172
[8]   An ionic liquid-type multiwall carbon nanotubes paste electrode for electrochemical investigation and determination of morphine [J].
Ensafi, Ali A. ;
Rezaei, B. ;
Krimi-Maleh, Hassan .
IONICS, 2011, 17 (07) :659-668
[9]   Sequential Determination of Benserazide and Levodopa by Voltammetric Method using Chloranil as a Mediator [J].
Ensafi, Ali A. ;
Arabzadeh, A. ;
Karimi-Maleh, H. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (08) :1572-1580
[10]   A spectroscopic study on applicability of spectral analysis for simultaneous quantification of L-dopa, benserazide and ascorbic acid in batch and flow systems [J].
Karpinska, J ;
Smyk, J ;
Wolyniec, E .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2005, 62 (1-3) :213-220